OcNOS-RON-6.3.1 : System Management Guide : System Management Command Reference : Coherent Optics Commands : show coherent-module monitoring-thresholds
show coherent-module monitoring-thresholds
Use this command to show alarms and warning thresholds of the coherent module.
Command Syntax
show coherent-module SLOTNUMBER monitoring-thresholds
Parameters
SLOTNUMBER
Slot number of the coherent module
Default
None
Command Mode
Exec mode
Applicability
This command was introduced in OcNOS-OTN version 1.0.2.
Example
#show coherent-module 6 monitoring-thresholds
---------------------------------------------------------------
Temperature [42.06 °C] : Monitoring Enabled
---------------------------------------------------------------
Temperature HIGH Alarm threshold : 80.00 °C
Temperature HIGH Warning threshold : 75.00 °C
Temperature LOW Warning threshold : 0.00 °C
Temperature LOW Alarm threshold : -5.00 °C
 
---------------------------------------------------------------
Voltage [3.336 V] : Monitoring Enabled
---------------------------------------------------------------
Voltage HIGH Alarm threshold : 3.000 V
Voltage HIGH Warning threshold : 3.100 V
Voltage LOW Warning threshold : 3.600 V
Voltage LOW Alarm threshold : 3.500 V
 
---------------------------------------------------------------
Input-Power [-50.00 dBm] : Monitoring Enabled
---------------------------------------------------------------
Input-Power HIGH Alarm threshold : 4.00 dBm
Input-Power HIGH Warning threshold : 2.00 dBm
Input-Power LOW Warning threshold : -15.00 dBm
Input-Power LOW Alarm threshold : -18.01 dBm
Permissible Input-Power HIGH Alarm threshold range : -11.00 dBm to 8.00 dBm
Permissible Input-Power HIGH Warning threshold range : -11.10 dBm to 6.99 dBm
Permissible Input-Power LOW Warning threshold range : -30.00 dBm to 5.99 dBm
Permissible Input-Power LOW Alarm threshold range : -40.00 dBm to 5.00 dBm
 
---------------------------------------------------------------
Output-Power [-0.07 dBm] : Monitoring Enabled
---------------------------------------------------------------
Output-Power HIGH Alarm threshold : 5.00 dBm
Output-Power HIGH Warning threshold : 3.50 dBm
Output-Power LOW Warning threshold : -11.00 dBm
Output-Power LOW Alarm threshold : -12.00 dBm
 
---------------------------------------------------------------
Pre-FEC BER [nan] : Monitoring Enabled (User-Thresholds)
---------------------------------------------------------------
Prefec signal-failure threshold : 4.120000e-03
Prefec signal-degrade threshold : 1.420000e-03
Prefec signal-clear threshold : 9.200000e-04
Last modified date: 07-14-2023