test-signal pattern-type
Use this command to configure the TLV type to be encoded in ETH-Test PDU.
Use no form of this command to reset the TLV pattern type to default.
Command Syntax
test-signal pattern-type (null-sig|null-sig-crc32|prbs|prbs-crc32)
no test-signal pattern-type
Parameters
null-sig
Specify test pattern as a Null signal without CRC-32
null-sig-crc32
Specify test pattern as a Null signal with CRC-32
prbs
Specify test pattern as a PRBS 2^31-1 without CRC-32
prbs-crc32
Specify test pattern as a PRBS 2^31-1 with CRC-32
Command Mode
Configure CFM ETH test mode
Default
Default TLV pattern type is Null signal.
Applicability
This command was introduced in OcNOS version 4.0.
Example
#configure terminal
(config)#ethernet cfm test-signal profile-name 123
(config-cfm-eth-tst)#test-signal pattern-type null-signal
 
(config-cfm-eth-tst)#no test-signal pattern-type