OcNOS-SP : Timing and Synchronization Guide : Precision Time Protocol Command Reference : PTP Commands : delay-asymmetry
delay-asymmetry
Use this command to set asymmetric delay in nanoseconds. The value can be entered as milliseconds or nanoseconds.
Note: Entering a value in both milliseconds and nanoseconds will result in the sum of the two values being set.
Use the no form of this command to set default value 0.
Command Syntax
delay-asymmetry {msec <-100-100>|nsec <-1000000-1000000>}
no delay-asymmetry
Parameters
msec <-100-100>
Value of latency in milliseconds.
nsec <-1000000-1000000>
Value of latency in nanoseconds.
Command Mode
PTP Clock Port mode
Applicability
This command introduced in OcNOS version 4.0.
Example
(config)#ptp clock 0 profile g8275.2
(config-ptp-clk)#clock-port 1
(config-clk-port)#delay-asymmetry msec 100 nsec 1000000
 
 
Last modified date: 06/30/2023