local-priority (ptp-clk mode)
Use this command to specify the local attribute of the local clock.
Use the no form of this command to set default value 128.
Note: Not supported for default profile.
Command Syntax
local-priority <1-255>
no local-priority
Parameters
<1-255>
A numerical value specifying the local priority
Command Mode
PTP Clock Mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
(config)#ptp clock 0 profile g8275.1
(config-ptp-clk)#local-priority 100
Last modified date: 06/30/2023