log-announce-interval
Use this command to set log-announce-interval. Applicable for only G.8275.2 profile, G 8265.1, and default profile.
Use the no form of this command to set default value:
• -3 for G 8275.2 profile
• 1 for default profile
• 1 for G 8265.1 profile
Command Syntax
log-announce-interval <-3-4>
no log-announce-interval
Parameters
<-3-4>
log-announce-interval range:
-3 to 3 for g8275.2
0 to 4 for default profile
-3 to 4 for g8265.1
Command Mode
PTP Clock Port Mode
Applicability
This command was introduced in OcNOS version 4.0.
Example
(config)#ptp clock 0 profile g8275.2
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-announce-interval -2
(config)#ptp clock 0 profile default
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-announce-interval 2
(config)#ptp clock 0 profile g8265.1
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-announce-interval 2
Last modified date: 06/30/2023