OcNOS-SP : Timing and Synchronization Guide : Precision Time Protocol Command Reference : PTP Commands : log-sync-interval
log-sync-interval
Use this command to set log-sync-interval. Applicable for only G.8275.2 profile, G 8265.1 profile, and default profile.
Use the no form of this command to set default value:
-6 for g8275.2 profile
0 for default profile
-5 for G 8265.1 profile
Command Syntax
log-sync-interval <-7-1>
no log-sync-interval
Parameters
<-7-1>
log-sync-interval range:
-7 to 0 for g8275.2
-1 to 1 for default profile
-7 to 4 for g8265.1
Command Mode
PTP Clock Port mode
Applicability
This command was introduced in OcNOS version 4.0.
Example
(config)#ptp clock 0 profile g8275.2
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-sync-interval -4
 
(config)#ptp clock 0 profile default
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-sync-interval -1
 
(config)#ptp clock 0 profile g8265.1
(config-ptp-clk)#clock-port 1
(config-clk-port)#log-sync-interval -1
 
Last modified date: 06/30/2023