servo-history
Use this command to enable servo-history with specified interval.
Use the no form of this command to disable servo-history.
Command Syntax
servo-history <1-60>
no servo-history
Parameters
<1-60>
Enable servo-history in interval of <1-60> minutes (default is 15 minutes)
Command Mode
PTP Clock Mode
Default
Default interval value is 15 minutes.
Applicability
This command was introduced in OcNOS version 4.0.
Example
(config)#ptp clock 0 profile g8275.1
(config-ptp-clk)#servo-history 2