OcNOS-SP : Timing and Synchronization Guide : Precision Time Protocol Command Reference : PTP Commands : show ptp servo
show ptp servo
Use this command to display servo information.
Command Syntax
show ptp servo
Parameters
None
Command Mode
Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ptp servo
PTP servo status for clock 0
Servo Config : Phase Correction
Servo State : Warmup
Servo State Duration : 04:26:07
Servo APTS Mode : N/A
Lock Status : Unlocked
Frequency Correction : 0.000 ppb
Phase Correction : 0.000 nsec
Offset From Master : 0.000 nsec
Mean Path Delay : 0 nsec
Sync Packet Rate : 0
Delay Packet Rate : 0