OcNOS-SP : Timing and Synchronization Guide : Synchronous Ethernet Command Reference : SyncE Commands : input-source
input-source
Use this command to set an input timing source. Synchronization packets are received from this source and sent to the clock selection algorithm.
Use the no form of this command to delete an input source.
Command Syntax
input-source <0-255>
no input-source
Parameters
<0-255>
Priority: 1 is the highest, 255 is the lowest; 0 means the source will not be considered by the clock selection algorithm
Default
The default value is 0 meaning the interface will not be considered by the clock selection algorithm.
Command Mode
Interface Synchronous Ethernet mode
Applicability
This command was introduced before OcNOS version 1.3.
Example
(config)#interface eth1
(config-if)#synce
(config-if-synce)#input-source 1
 