OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : CFM and Y.1731 Commands : abort test-signal domain
abort test-signal domain
Use this command to abort pre-configured test session.
Command Syntax
abort test-signal domain DOMAIN_NAME ma MA_NAME mep MEPID
Parameters
domain
Specify domain.
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
ma
Specify Maintenance association name
MA_NAME
Enter maintenance association name. If ma-type is character string then maximum length of ma-name is 6 else if it’s integer then maximum is 2-octets.
mep
Specify mep
MEPID
Enter the MEPID ranging from <1-8191>
Command Mode
Exec mode
Default
None
Applicability
This command was introduced in OcNOS version 4.0.
Example
#abort test-signal domain 12345 ma 43982 mep 21
 
 
 
Last modified date: 10/20/2023