bins-per-ifdv-interval
Use this command to set the number of measurement bins per measurement interval for an inter-frame delay for a two-way performance monitoring frame delay measurements on a specific MEP.
Use the no form to set the number of measurement bins per measurement interval for an inter-frmae delay for a two-way performance monitoring frame delay measurements on a specific MEP to its default (2).
Command Syntax
bins-per-ifdv-interval <2-10>
no bins-per-ifdv-interval
Parameters
<2-10>
Number of inter-frame delay bins to be created
Default
2
Command Mode
Ethernet CFM delay measurement mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#configure terminal
(config)#ethernet cfm delay-measurement profile-name PROF1
(config-cfm-dm)# bins-per-ifdv-interval 3