OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : CFM and Y.1731 Commands : clear ethernet cfm lm history
clear ethernet cfm lm history
Use this command to clear the CFM frame loss measurement history statistics.
Command Syntax
clear ethernet cfm lm history mep MEPID domain DOMAIN_NAME ma MA_NAME s
Parameters
MEPID
Local MEP identifier <1-8191>
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
Enter maintenance association name. If ma-type is character string then maximum length of ma-name is 6 else if it’s integer then maximum is 2-octets.
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#clear ethernet cfm lm history mep 201 domain 12345 ma 123
 
Last modified date: 10/20/2023