OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : CFM and Y.1731 Commands : delay-measurement type on-demand
delay-measurement type on-demand
Use this command to schedule an on-demand CFM delay measurement session.
Command Syntax
delay-measurement type on-demand profile-name WORD rmep (mac-address MAC|RMEPID) start-time (immediate|relative HH:MM:SS|absolute HH:MM:SS <1-31> MONTH <1993- 2035>) repetition-period <6000-4294967295> mep MEPID domain DOMAIN_NAME
Parameters
WORD
Delay measurement profile name
MAC
Destination MAC address in HHHH.HHHH.HHHH format
RMEPID
Destination peer MEP identifier <1-8191>
start-time
Measurement session start time
immediate
Start immediately
relative HH:MM:SS
 
Relative time to start from the current system time
absolute HH:MM:SS <1-31> MONTH <1993-2035>
 
Scheduled date and time to start; for the month, specify the first three letters
stop-time
Measurement session stop time
none
Never stop
relative HH:MM:SS
 
Relative time to stop from the current system time
absolute HH:MM:SS <1-31> MONTH <1993-2035>
 
Scheduled date and time to stop; for the month, specify the first three letters
<6000-4294967295>
 
Repetition time in centiseconds
MEPID
Local MEP identifier <1-8191>
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
Enter maintenance association name. If ma-type is character string then maximum length of ma-name is 6 else if it’s integer then maximum is 2-octets.
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#delay-measurement type on-demand profile-name PROF1 rmep 101 start-time relative 00:00:03 stop-time relative 00:03:00 repetition-period 7000 mep 123 domain no_name ma
123
 
Last modified date: 10/20/2023