loss-measurement type on-demand
Use this command to schedule an on-demand CFM loss measurement session.
Command Syntax
loss-measurement type on-demand profile-name WORD rmep (mac-address MAC|mep-id MEPID) start-time (immediate|relative HH:MM:SS|absolute HH:MM:SS <1-31> MONTH
<1993-2035>) stop-time (none|relative HH:MM:SS|absolute HH:MM:SS <1-31> MONTH
<1993-2035>) repetition-period <6000-4294967295> mep MEPID domain DOMAIN_NAME
ma MA_NAME
Parameters
WORD
Loss measurement profile name
MAC
Destination MAC address in HHHH.HHHH.HHHH format
MEPID
Remote MEP identifier <1-8191> to which to send the service OAM loss measurement frame
start-time
Measurement session start time
immediate
Start immediately
relative HH:MM:SS
Relative time to start from the current system time
absolute HH:MM:SS <1-31> MONTH <1993-2035>
Scheduled date and time to start; for the month, specify the first three letters
stop-time
Measurement session stop time
none
Never stop
relative HH:MM:SS
Relative time to stop from the current system time
absolute HH:MM:SS <1-31> MONTH <1993-2035>
Scheduled date and time to stop; for the month, specify the first three letters
repetition-period
Repetition time between measurement intervals
<0-4294967295>
Repetition time in seconds
MEPID
Remote MEP identifier <1-8191> to which to send the service OAM loss measurement frame
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
MA name
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#loss-measurement type on-demand profile-name slm rmep mac-address 0018.2323.1234 start-time immediate stop-time none repetition-period 9000 mep 201 domain 12345 ma 123
Last modified date: 10/20/2023