measurement-interval
Use this command to set the measurement interval for frame loss or delay measurement session.
Use the no form of this command to set the measurement interval to its default value (15 minutes).
Command Syntax
Loss measurement:
measurement-interval <1-525600>
no measurement-interval
Delay measurement:
measurement-interval <1-1440>
no measurement-interval
Parameters
For frame loss measurement:
<1-525600>
Measurement interval in minutes
For frame delay measurement:
<1-1440>
Measurement interval in minutes
Default
15 minutes
Command Mode
Ethernet CFM loss measurement mode and Ethernet CFM delay measurement mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
Loss measurement:
#configure terminal
(config)#ethernet cfm loss-measurement profile-name PROF1
(config-cfm-lm)#measurement-interval 500
Delay measurement:
#configure terminal
(config)#ethernet cfm delay-measurement profile-name PROF1
(config-cfm-dm)# measurement-interval 1
Last modified date: 10/20/2023