OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : G8031 ELPS Commands : level
level
Use this command to associate CFM with g8031 protection group.
Use the no form of this command to disassociate CFM from g8031 protection group.
Note: It is mandatory for Working-port MEP and Protection-Port MEP to be in different Maintenance Domain but in same Maintenance Level. Moreover, Maintenance Association Vlan-id should be same as g8031 primary-vlan id. If both the conditions are met then, g8031 protection group can be associated to using the 'level' command.
Command Syntax
level <0-7>
no level
Parameters
<0-7>
domain level.
Command Mode
G8031 Switching Mode.
Applicability
This command was introduced before OcNOS version 5.0.
Examples
#configure terminal
(config)#g8031 eps-id 10 bridge 1
(g8031-config-switching)#mode one-and-one-bidirectional
(g8031-config-switching)#level 3
Last modified date: 10/20/2023