Log Message
Edge1-SiteX#configure terminal | Enter configure mode. |
Edge1-SiteX(config)#logging level nsm 4 | Enable Operational log to display recovery message |
Edge1-SiteX(config)#commit | Commit the candidate configuration to the running configuration. |
Edge1-SiteX(config)#exit | Exit interface mode |
2017 Sep 18 11:52:12 : NSM : CRITI : [IFMGR_IF_DOWN_2]: Interface xe11 changed state to down
(config-if)#no shut
(config-if)#2017 Sep 18 11:52:15 : NSM : CRITI : [IFMGR_IF_UP_2]: Interface xe11 changed state to up
2017 Sep 18 11:52:15 : NSM : WARN : [VXLAN_OPR_ACCESSPORT_UP_4]: VXLAN Access port on xe11 is up
2017 Sep 18 11:52:15 : NSM : CRITI : [IFMGR_ERR_DISABLE_DOWN_2]: Interface xe11 moved to errdisable state due to link-flap
2017 Sep 18 11:52:15 : NSM : CRITI : [IFMGR_IF_DOWN_2]: Interface xe11 changed state to down
Note: Interface xe11 recovered from the ErrDisable state after a 50 second time-out.
Last modified date: 10/12/2023