ac-description
Use this command to add description for an attachment circuit specific for a VPLS instance
Use the no parameter with this command to remove the description
Command Syntax
ac-description LINE
Parameter
LINE
Characters describing this AC
Default
By default, ac description LINE is disabled
Command Mode
Interface VPLS
Applicability
This command was introduced before OcNOS version 1.3.
Example
This example shows the configuration of description for attachment circuit specific to VPLS instance
#configure terminal
(config)#interface xe1
(config-if)#mpls-vpls vpls1 service-template st1
(config-if-vpls)#ac-description AC1_VPLS1