OcNOS-SP : Segment Routing Guide : Path Computation Element Communication Protocol Command Reference : PCEP Commands : tolerance deadtimer
tolerance deadtimer
Use this command to set the tolerance dead-timer.
Use the no form of this command to set the tolerance dead-timer to its default (0 seonds)
Command Syntax
tolerance deadtimer <1-255>
no tolerance deadtimer
Parameters
<1-255>
Tolerance dead-timer interval. The default is 0 seconds.
Default
0 seconds
Command Mode
PCEP mode
Applicability
This command was introduced in OcNOS version 4.0.
Example
#configure terminal
(config)#pce configuration 127
(config-pcep)#tolerance deadtimer 50