OcNOS-SP : Multi-Protocol Label Switching Guide : RSVP-TE Command Reference : RSVP-TE Commands : secondary retry-timer
secondary retry-timer
Use this command to specify a retry interval for an RSVP Trunk. When the ingress tries to configure an LSP and the setup fails due to the receipt of a path error message, the system waits for the time configure by this command before retrying the LSP setup process.
Use the no parameter to revert to the default.
Command Syntax
secondary retry-timer <1-6OO>
no secondary retry-timer
Parameter
<1-6OO>
Interval after which the system should retry setting up the LSP, in seconds
Default
By default, retry time is 30 seconds
Command Mode
Trunk mode
Applicability
This command was introduced before OcNOS version 1.3.
Examples
#configure terminal
(config)#rsvp-trunk mytrunk
(config-trunk)#secondary retry-timer 12
Last modified date: 10/17/2023