QSFP-DD Commands
This chapter is a reference for the QSFP-DD configuration and status commands:
•	ha
•	hw
•	la
•	lw
•	show qsfp-dd user-threshold status
•	threshold (host-lane mode)
•	threshold (media-lane mode)
•	threshold (QSFP-DD mode)
application 
Use this command to select the application ID to be configured for this QSFP-DD module. 
Use the no parameter with this command to remove this configuration. If no application is configured then application ID 1 will be selected as per module default.
Note:	Only 400G application modes are supported.
Note:	For checking the supported applications modes show qsfp-dd <port no.> advertisement applications command, see the example.
Example:
OcNOS#show qsfp-dd 49 application
 
Port Number                    : 49
-----------------------------------
   User Config    |   H/W Config
-----------------------------------
   Application 2  |   Application 2
 
OcNOS#sh qsfp-dd 49 advertisement applications
 
Port Number                   : 49
> Application 1:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZR, DWDM, Amplified
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8.000000
         Lane Assigned        : Lane-1
  Application 2:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZR, Single Wavelen., Unamp.
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8.000000
         Lane Assigned        : Lane-1
  Application 3:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 400ZR, DWDM, Amplified
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8.000000
         Lane Assigned        : Lane-1
  Application 4:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-1
    | Media |
         Interface            : ZR400-OFEC-16QAM
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8.000000
         Lane Assigned        : Lane-1
  Application 5:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : ZR400-OFEC-16QAM
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8.000000
         Lane Assigned        : Lane-1
  Application 6:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : ZR300-OFEC-8QAM
         Application BR       : 360.831281
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-8QAM
         Bits Per Unit Intvl  : 6.000000
         Lane Assigned        : Lane-1
  Application 7:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : ZR200-OFEC-QPSK
         Application BR       : 240.554187
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4.000000
         Lane Assigned        : Lane-1
  Application 8:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2.000000
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : ZR100-OFEC-QPSK
         Application BR       : 120.277094
         Lane Count           : 1
         Lane Sig BR          : 30.069273
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4.000000
         Lane Assigned        : Lane-1
Command Syntax
application <2-15>
Parameters
<2-15>
Configurable application IDs
Command Mode
QSFP-DD mode
Default
By default, application ID 1 is selected.
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#application 8
(config-qsfp-dd)#commit
(config-qsfp-dd)#no application
(config-qsfp-dd)#commit
(config-qsfp-dd)#
 
laser channel
Use this command to configure the laser channel number for the QSFP-DD module.
Command Syntax
laser channel NUMBER
no laser channel
Parameters
NUMBER
channel number
Default
None.
Command Mode
QSFP-DD mode
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#laser channel 10
(config-qsfp-dd)#commit
(config-qsfp-dd)#no laser channel
(config-qsfp-dd)#commit
(config-qsfp-dd)#
laser grid
Use this command to configure the laser grid spacing frequency for the QSFP-DD module.
Command Syntax
laser grid (3p125|6p25|12p5|25|33|50|75|100)
no laser grid
Parameters
3p125     
3.125 GHz
6p25      
6.25 GHz
12p5      
12.5 GHz
25        
25 GHz
33        
33 GHz
50        
50 GHz
75        
75 GHz
100       
100 GHz
Default
None.
Command Mode
QSFP-DD mode
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#laser grid 50
(config-qsfp-dd)#commit
(config-qsfp-dd)#no laser grid
(config-qsfp-dd)#commit
(config-qsfp-dd)#
laser fine-tune-freq
Use this command to configure the laser fine tune frequency offset for the QSFP-DD module.
Command Syntax
laser fine-tune-freq VALUE
no laser fine-tune-freq
Parameters
VALUE
Fine tune frequency offset in GHz
Default
None.
Command Mode
QSFP-DD mode
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#laser fine-tune-freq 1.5
(config-qsfp-dd)#commit
(config-qsfp-dd)#no laser fine-tune-freq
(config-qsfp-dd)#commit
(config-qsfp-dd)#
laser output-power
Use this command to configure the laser target output power for the QSFP-DD module.
Command Syntax
laser output-power VALUE
no laser output-power
Parameters
VALUE
Laser target output power
Default
None.
Command Mode
QSFP-DD mode
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#laser output-power -9.2
(config-qsfp-dd)#commit
(config-qsfp-dd)#no laser output-power
(config-qsfp-dd)#commit
(config-qsfp-dd)#
loopback 
Use this command to configure the loopback type (input, output, both) on the QSFP-DD module host/media side. If the loopback type is supported by the QSFP-DD module this will enable the loopback function. 
Use the no parameter to remove this configuration and disable the loopback function.
Command Syntax
loopback (in|out|both) (host|media)
no loopback (host|media)
Parameters
in
Configure input loopback
out
Configure output looback
both
Configure input and output loopback
host
Configure host side
media
Configure media side
Command Mode
QSFP-DD mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
(config)#qsfp-dd 0
(config-qsfp-dd)#loopback in host
(config-qsfp-dd)#loopback out media
(config-qsfp-dd)#commit
(config-qsfp-dd)#loopback both media
(config-qsfp-dd)#no loopback host
(config-qsfp-dd)#commit
(config-qsfp-dd)#
 
prbs 
Use these commands to configure the PRBS pattern generator/checker type to be used for diagnostics of the QSFP-DD module host/media side and to configure the PRBS pattern generator/checker location (pre-fec/post-fec) on the QSFP-DD module host/media side. If the generator/checker pattern type and location are supported by the QSFP-DD module this will enable the selected function. 
Use the no parameter to remove this configuration and disable the generator/checker function.
Command Syntax
prbs (generator|checker) type (31q|31|23q|23|15q|15|13q|13|9q|9|7q|7|ssprq) (host|media)
prbs (generator|checker) (pre-fec|post-fec) (host|media)
no prbs (generator|checker) type (host|media)
no prbs (generator|checker) (host|media)
Parameters
generator
Configure the pattern generator
checker 
Configure the pattern checker
31q 
Configure PRBS-31Q type 
31
Configure PRBS-31 type
23q
Configure PRBS-23Q type
23
Configure PRBS-23 type
15q
Configure PRBS-15Q type
15
Configure PRBS-15 type
13q
Configure PRBS-13Q type
13
Configure PRBS-13 type
9q
Configure PRBS-9Q type
9
Configure PRBS-9 type
7q
Configure PRBS-7q type
7 
Configure PRBS-7 type
ssprq 
Configure SSPRQ type
pre-fec
Configure to generate before the FEC encoder / check before the FEC decoder
post-fec
Configure to generate after the FEC encoder / check after the FEC decoder
host
Configure host side
media 
Configure media side
Command Mode
QSFP-DD mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#prbs generator type 15 host
(config-qsfp-dd)#prbs checker type 23q host
(config-qsfp-dd)#prbs generator type 7q media
(config-qsfp-dd)#prbs checker type ssprq media
(config-qsfp-dd)#commit
(config-qsfp-dd)#no prbs generator type host
(config-qsfp-dd)#no prbs checker type media
(config-qsfp-dd)#commit
(config-qsfp-dd)#
qsfp-dd 
Use this command to select a QSFP-DD port to configure and enter the qsfp-dd command mode. Use the exit command to quit from this mode.
Command Syntax
qsfp-dd PORTNUM
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Configure mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#
 
rx-output eq-pre-cursor-target
Use this command to configure the Rx output equalizer pre-cursor target override value.
Use the  no form of this command to remove the Rx output equalizer pre-cursor target override value.
Command Syntax
rx-output eq-pre-cursor-target <1-15>
no rx-output eq-pre-cursor-target
Parameters
<1-15> 
Output equalizer pre-cursor target value
Default
None.
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#rx-output eq-pre-cursor-target 4
(config-qsfp-dd)#commit
(config-qsfp-dd)#no rx-output eq-pre-cursor-target
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 2
(config-qsfp-dd-host)#rx-output eq-pre-cursor-target 1
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no rx-output eq-pre-cursor-target
(config-qsfp-dd-host)#commit
 
rx-output eq-post-cursor-target
Use this command to configure the Rx output equalizer post-cursor target override value.
Use the no form of this command to remove the Rx output equalizer post-cursor target override value..
Command Syntax
rx-output eq-post-cursor-target <1-15>
no rx-output eq-post-cursor-target
Parameters
<1-15> 
Output equalizer post-cursor target value
Default
None.
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#rx-output eq-post-cursor-target 2
(config-qsfp-dd)#commit
(config-qsfp-dd)#no rx-output eq-post-cursor-target
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 7
(config-qsfp-dd-host)#rx-output eq-post-cursor-target 6
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no rx-output eq-post-cursor-target
(config-qsfp-dd-host)#commit
rx-output amp-target
Use this command to configure the Rx output amplitude target override value.
Use the no form of this command to remove the Rx output amplitude target override value.
Command Syntax
rx-output amp-target <0-15>
no rx-output amp-target
Parameters
<1-15> 
Output amplitude target value
Default
None.
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#rx-output amp-target 0
(config-qsfp-dd)#commit
(config-qsfp-dd)#no rx-output amp-target
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 3
(config-qsfp-dd-host)#rx-output amp-target 1
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no rx-output amp-target
(config-qsfp-dd-host)#commit
 
rx cdr-bypass
Use this command to enable the Rx CDR bypass.
Use the  no form of this command to disable the Rx CDR bypass.
Command Syntax
rx cdr-bypass
no rx cdr-bypass
Parameters
None
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#rx cdr-bypass
(config-qsfp-dd)#commit
(config-qsfp-dd)#no rx cdr-bypass
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 2
(config-qsfp-dd-host)#rx cdr-bypass
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no rx cdr-bypass
 
show qsfp-dd advertisement applications
Use this command to show QSFP-DD module advertised applications.
Command Syntax
show qsfp-dd PORTNUM advertisement applications
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement applications
 
Port Number                   : 0
> Application 1:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZR, DWDM, Amplified
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 2:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZR, Single Wavelen., Unamp.
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 3:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 400ZR, DWDM, Amplified
         Application BR       : 478.75
         Lane Count           : 1
         Lane Sig BR          : 59.84375
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 4:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZRP, DWDM, amplified 120Km
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 5:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZRP, DWDM, Amplified 450Km
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 6:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 400ZRP, DWDM, Amplified 450Km
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 7:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, Amplified 600Km
         Application BR       : 360.831281
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-8QAM
         Bits Per Unit Intvl  : 6
         Lane Assigned        : Lane-1
  Application 8:
    | Host |
         Interface            : 400GAUI-8 C2M
         Application BR       : 425.00
         Lane Count           : 8
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-1
    | Media |
         Interface            : 400ZRP, DWDM, amplified 450Km (Enhanced Constellation)
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 9:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 400ZRP, DWDM, amplified 450Km (Enhanced Constellation)
         Application BR       : 481.108374
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-16QAM
         Bits Per Unit Intvl  : 8
         Lane Assigned        : Lane-1
  Application 10:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, amplified 600Km (Enhanced Constellation)
         Application BR       : 360.831281
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-8QAM
         Bits Per Unit Intvl  : 6
         Lane Assigned        : Lane-1
  Application 11:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, Amplified 1000Km
         Application BR       : 240.554187
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4
         Lane Assigned        : Lane-1
  Application 12:
    | Host |
         Interface            : CAUI-4 C2M without FEC
         Application BR       : 103.13
         Lane Count           : 4
         Lane Sig BR          : 25.78125
         Modulation Format    : NRZ
         Bits Per Unit Intvl  : 1
         Lane Assigned        : Lane-5/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, Amplified 1000Km
         Application BR       : 240.554187
         Lane Count           : 1
         Lane Sig BR          : 60.1385468
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4
         Lane Assigned        : Lane-1
  Application 13:
    | Host |
         Interface            : 100GAUI-2 C2M
         Application BR       : 106.25
         Lane Count           : 2
         Lane Sig BR          : 26.5625
         Modulation Format    : PAM4
         Bits Per Unit Intvl  : 2
         Lane Assigned        : Lane-7/Lane-5/Lane-3/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, amplified 2000Km
         Application BR       : 120.277094
         Lane Count           : 1
         Lane Sig BR          : 30.069273
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4
         Lane Assigned        : Lane-1
  Application 14:
    | Host |
         Interface            : CAUI-4 C2M without FEC
         Application BR       : 103.13
         Lane Count           : 4
         Lane Sig BR          : 25.78125
         Modulation Format    : NRZ
         Bits Per Unit Intvl  : 1
         Lane Assigned        : Lane-5/Lane-1
    | Media |
         Interface            : 100ZRP, DWDM, amplified 2000Km
         Application BR       : 120.277094
         Lane Count           : 1
         Lane Sig BR          : 30.069273
         Modulation Format    : DP-QPSK
         Bits Per Unit Intvl  : 4
         Lane Assigned        : Lane-1
 
show qsfp-dd advertisement controls
Use this command to show QSFP-DD module advertised controls.
Command Syntax
show qsfp-dd PORTNUM advertisement controls
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement controls
 
Port Number                    : 0
Wavelength Control             : Yes
Tunable Transmitter            : Yes
Tx Output Squelching           : Not Supported
Forced Tx Output Squelching    : No
Tx Output Squelching Disable   : No
Tx Output Disable              : Yes
Input Polarity Flip Tx         : Yes
Rx Output Squelching Disable   : Yes
Rx Output Disable              : Yes
Output Polarity Flip Rx        : Yes
 
show qsfp-dd advertisement diagnostics host
Use this command to show QSFP-DD module advertised host side diagnostics.
Command Syntax
show qsfp-dd PORTNUM advertisement diagnostics host
Parameters
PORTNUM
   QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 advertisement diagnostics host
 
Port Number                    : 0
| Supported Loopback Modes |
     Output                    : Yes
     Input                     : Yes
     Per Lane                  : Yes
| Reporting Capabilities |
     Input SNR                 : No
     FEC                       : Yes
| PRBS Checker |
     Post FEC                  : Yes
     Pre FEC                   : Yes
     Types                     : PRBS-31Q, PRBS-31, PRBS-23Q, PRBS-23, PRBS-15Q, PRBS-15, PRBS-13Q, PRBS-13, PRBS-9Q, PRBS-9, PRBS-7Q, PRBS-7
| PRBS Generator |
     Post FEC                  : Yes
     Pre FEC                   : Yes
     Types                     : PRBS-31Q, PRBS-31, PRBS-23Q, PRBS-23, PRBS-15Q, PRBS-15, PRBS-13Q, PRBS-13, PRBS-9Q, PRBS-9, PRBS-7Q, PRBS-7
 
show qsfp-dd advertisement diagnostics media
Use this command to show QSFP-DD module advertised media side diagnostics.
Command Syntax
show qsfp-dd PORTNUM advertisement diagnostics media
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 advertisement diagnostics media
 
Port Number                    : 0
| Supported Loopback Modes |
     Output                    : Yes
     Input                     : No
     Per Lane                  : Yes
| Reporting Capabilities |
     Input SNR                 : Yes
     FEC                       : Yes
| PRBS Checker |
     Post FEC                  : Yes
     Pre FEC                   : No
     Types                     : PRBS-31, PRBS-23, PRBS-15, PRBS-7
| PRBS Generator |
     Post FEC                  : Yes
     Pre FEC                   : Yes
     Types                     : PRBS-31, PRBS-23, PRBS-15, PRBS-7
 
show qsfp-dd advertisement diagnostics module
Use this command to show QSFP-DD module advertised diagnostics.
Command Syntax
show qsfp-dd PORTNUM advertisement diagnostics module
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 advertisement diagnostics module
 
Port Number                    : 0
| Supported Loopback Modes |
     Simul. Host & Media Side  : Yes
| Reporting Capabilities |
     Bit Error Ratio           : Yes
     Bits & Errors Counting    : Yes
show qsfp-dd advertisement durations
Use this command to show module advertised durations
Command Syntax
show qsfp-dd PORTNUM advertisement durations
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement durations
 
Port Number                    : 0
ModSel Wait                    : 4 us
DP Init Max                    : 10 s <= t < 1 min
DP Deinit Max                  : 1 s <= t < 5 s
DP Tx Turn On Max              : 50 ms <= t < 100 ms
DP Tx Turn Off Max             : 1 ms <= t < 5 ms
Module Power Up Max            : 10 s <= t < 1 min
Module Power Down Max          : 1 s <= t < 5 s
show qsfp-dd advertisement laser
Use this command to show QSFP-DD module advertised laser controls.
Command Syntax
show qsfp-dd PORTNUM advertisement laser
Parameters
PORTNUM 
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 advertisement laser
 
Port Number                        : 0
Supported Grids                    : 6.25 GHz, 12.5 GHz, 25 GHz, 50 GHz, 100 GHz, 75 GHz
   6.25 GHz Channels               : Low=191.275 THz, High=196.125 THz, Total=776
   12.5 GHz Channels               : Low=191.275 THz, High=196.125 THz, Total=388
   25 GHz Channels                 : Low=191.275 THz, High=196.125 THz, Total=194
   50 GHz Channels                 : Low=191.300 THz, High=196.100 THz, Total=96
   100 GHz Channels                : Low=191.300 THz, High=196.100 THz, Total=48
   75 GHz Channels                 : Low=191.300 THz, High=196.100 THz, Total=64
Fine Tuning Support                : Yes
   Fine Tuning Resolution          : 0.001 GHz
   Fine Tuning Low Offset          : -6.000 GHz
   Fine Tuning High Offset         : 6.000 GHz
Output Power Programmable Per Lane : Yes
   Min Output Power Programmable   : -22.90 dBm
   Max Output Power Programmable   : 4.00 dBm
 
show qsfp-dd advertisement monitors host
Use this command to show QSFP-DD module advertised host side monitors.
Command Syntax
show qsfp-dd PORTNUM advertisement monitors host
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement monitors host
 
Port Number                      : 0
Pre-FEC BER Minimum Input        : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
Pre-FEC BER Maximum Input        : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
Pre-FEC BER Average Input        : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
Pre-FEC BER Current Value Input  : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
FERC Minimum Input               : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
FERC Maximum Input               : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
FERC Average Input               : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
FERC Current Value Input         : Yes [Lane 1, Lane 3, Lane 5, Lane 7]
 
| Link Performance |
     Tx FDD                      : Yes
     Tx FED                      : Yes
 
show qsfp-dd advertisement monitors media
Use this command to show QSFP-DD module advertised media side monitors.
Command Syntax
show qsfp-dd PORTNUM advertisement monitors media
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement monitors media
 
Port Number                        : 0
Rx Optical Power                   : Yes
Tx Optical Power                   : Yes
Tx Bias                            : Yes
Rx Los                             : Yes
Tx Failure                         : Yes
Rx CDR LOL                         : Yes
Laser Age                          : Yes [Lane 1]
Pre-FEC BER Minimum Input          : Yes [Lane 1]
Pre-FEC BER Maximum Input          : Yes [Lane 1]
Pre-FEC BER Average Input          : Yes [Lane 1]
Pre-FEC BER Current Value Input    : Yes [Lane 1]
FERC Minimum Input                 : Yes [Lane 1]
FERC Maximum Input                 : Yes [Lane 1]
FERC Average Input                 : Yes [Lane 1]
FERC Current Value Input           : Yes [Lane 1]
Modular Bias X/I                   : Yes [Lane 1]
Modular Bias X/Q                   : Yes [Lane 1]
Modular Bias Y/I                   : Yes [Lane 1]
Modular Bias Y/Q                   : Yes [Lane 1]
Modular Bias X_Phase               : Yes [Lane 1]
Modular Bias Y_Phase               : Yes [Lane 1]
CD - high granularity, short link  : Yes [Lane 1]
CD - low granularity, long link    : Yes [Lane 1]
DGD                                : Yes [Lane 1]
SOPMD - high granularity           : Yes [Lane 1]
PDL                                : Yes [Lane 1]
OSRN                               : Yes [Lane 1]
eSRN                               : Yes [Lane 1]
CFO                                : Yes [Lane 1]
Tx Power                           : Yes [Lane 1]
Rx Total Power                     : Yes [Lane 1]
Rx Signal Power                    : Yes [Lane 1]
SOP ROC                            : Yes [Lane 1]
SOPMD - low granularity            : Yes [Lane 1]
 
| FEC Performance |
     Rx Bits                       : Yes
     Rx Correct Bits               : Yes
     Rx Frames                     : Yes
     Rx Uncorrect Frames           : Yes
 
| Link Performance |
     Rx DSP CCD                    : Yes
     Rx DSP DGD                    : Yes
     Rx SOPM                       : Yes
     Rx PDL                        : Yes
     Rx oSNR                       : Yes
     Rx eSNR                       : Yes
     Rx CFO                        : Yes
     Rx EvmModem                   : No
     Tx Power                      : Yes
     Rx Input Optical Power        : Yes
     Rx input Optical Signal Power : Yes
     Rx SOPCR                      : Yes
     Rx SOPMD Low Granularity      : No
     Rx Clock Recovery Monitor     : No
     Rx FDD                        : Yes
     Rx FEC                        : Yes
show qsfp-dd advertisement monitors module
Use this command to show QSFP-DD module advertised monitors
Command Syntax
show qsfp-dd PORTNUM advertisement monitors module
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 advertisement monitors module
 
Port Number                    : 0
Voltage                        : Yes
Temperature                    : Yes
TEC Current                    : Yes
Laser Temperature              : Yes
Laser Temperature [2]          : No
 
Rx Power                       : Yes
Rx Signal Power                : Yes
show qsfp-dd advertisement pages
Use this command to show QSFP-DD module advertised supported pages.
Command Syntax
show qsfp-dd PORTNUM advertisement pages
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 application
 
Port Number                    : 0
-----------------------------------
   User Config    |   H/W Config
-----------------------------------
   None           |   Application 1
OcNOS>show qsfp-dd 0 advertisement pages
 
Port Number                    : 0
Network Path                   : No
VDM                            : Yes
VDM Support                    : Groups 1-2 (Page 20h-21h, 24h-25h, 28h-29h, first 1/2 of 2Ch, 2Dh)
Diagnostics                    : Yes
User(Page 03h)                 : Yes
Banks(Page 10h-1Fh)            : Bank 0 (8 Lanes)
show qsfp-dd advertisement si
Use this command to display which signal integrity configuration capabilities the transceiver supports.
Command Syntax
show qsfp-dd <port> advertisement si
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#show qsfp-dd 0 advertisement si
 
-------------------------------------------------
                    Codes
-------------------------------------------------
Tx Equalization     >  1 - 12  : 1dB - 12db
                       13 - 15 : Vendor Specific
-------------------------------------------------
Rx Pre-Cursor Eq    >  1 - 7   : 0.5 - 3.5dB
                       8 - 10  : Reserved
                       11 - 15 : Vendor Specific
-------------------------------------------------
Rx Post-Cursor Eq   >  1 - 7   : 1 - 7dB
                       8 - 10  : Reserved
                       11 - 15 : Vendor Specific
-------------------------------------------------
Rx Amplitude        >  0       : 100-400mV (P-P)
                       1       : 300-600mV (P-P)
                       2       : 400-800mV (P-P)
                       3       : 600-1200mV (P-P)
                       4 - 15  : Reserved
-------------------------------------------------
Port Number                    : 0
 
Manual Tx Input Eq.            : No
 
Rx Output Eq. Type             : P-P with constant amplitude/NA/Unknown
 
Rx Output Amplitude            : No
 
Rx Output Eq.                  : Pre and post-cursor
Rx Output Eq. Pre-Cursor Max   : Code 7(3.5dB)
Rx Output Eq. Post-Cursor Max  : Code 7(7dB)
 
Tx CDR Supported               : Yes
Tx CDR Bypass Supported        : No
 
Rx CDR Supported               : Yes
Rx CDR Bypass Supported        : No
show qsfp-dd si status
Use this command to display what is the current signal integrity configuration status. It displays what is the current user configuration and what are the values programmed in the transceiver hardware.
Command Syntax
show qsfp-dd <port> si status
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#show qsfp-dd 0 si status
 
Port Number                    : 0
 
--------------------------------------------------------
      Parameter      | Lane | User Config | H/W Config |
--------------------------------------------------------
 Rx Pre-Cursor Eq    | 1    | None        | 11         |
                     | 2    | None        | 11         |
                     | 3    | None        | 11         |
                     | 4    | None        | 11         |
                     | 5    | None        | 11         |
                     | 6    | None        | 11         |
                     | 7    | None        | 11         |
                     | 8    | None        | 11         |
--------------------------------------------------------
 Rx Post-Cursor Eq   | 1    | None        | 11         |
                     | 2    | None        | 11         |
                     | 3    | None        | 11         |
                     | 4    | None        | 11         |
                     | 5    | None        | 11         |
                     | 6    | None        | 11         |
                     | 7    | None        | 11         |
                     | 8    | None        | 11         |
--------------------------------------------------------
 Tx CDR Bypass       | 1    | None        | Disabled   |
                     | 2    | None        | Disabled   |
                     | 3    | None        | Disabled   |
                     | 4    | None        | Disabled   |
                     | 5    | None        | Disabled   |
                     | 6    | None        | Disabled   |
                     | 7    | None        | Disabled   |
                     | 8    | None        | Disabled   |
--------------------------------------------------------
 Rx CDR Bypass       | 1    | None        | Disabled   |
                     | 2    | None        | Disabled   |
                     | 3    | None        | Disabled   |
                     | 4    | None        | Disabled   |
                     | 5    | None        | Disabled   |
                     | 6    | None        | Disabled   |
                     | 7    | None        | Disabled   |
                     | 8    | None        | Disabled   |
--------------------------------------------------------
 
show qsfp-dd application
Use this command to show QSFP-DD module current selected application.
Command Syntax
show qsfp-dd PORTNUM application
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 application
 
Port Number                    : 0
-----------------------------------
   User Config    |   H/W Config
-----------------------------------
   None           |   Application 1
 
show qsfp-dd diagnostics host
Use this command to show QSFP-DD module host side diagnostics information.
Command Syntax
show qsfp-dd PORTNUM diagnostics host
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 diagnostics host
 
Port Number                    : 0
----------------------------------------------------
       Attribute      | Lane |        Value        |
----------------------------------------------------
Bit Error Ratio       |  1   | 0.00e+00            |
                      |  2   | 0.00e+00            |
                      |  3   | 0.00e+00            |
                      |  4   | 0.00e+00            |
                      |  5   | 0.00e+00            |
                      |  6   | 0.00e+00            |
                      |  7   | 0.00e+00            |
                      |  8   | 0.00e+00            |
Bit Error Ratio(G)    |  1   | 0.00e+00            |
                      |  2   | 0.00e+00            |
                      |  3   | 0.00e+00            |
                      |  4   | 0.00e+00            |
                      |  5   | 0.00e+00            |
                      |  6   | 0.00e+00            |
                      |  7   | 0.00e+00            |
                      |  8   | 0.00e+00            |
Error Count           |  1   | 0                   |
                      |  2   | 0                   |
                      |  3   | 0                   |
                      |  4   | 0                   |
                      |  5   | 0                   |
                      |  6   | 0                   |
                      |  7   | 0                   |
                      |  8   | 0                   |
Bit Count             |  1   | 0                   |
                      |  2   | 0                   |
                      |  3   | 0                   |
                      |  4   | 0                   |
                      |  5   | 0                   |
                      |  6   | 0                   |
                      |  7   | 0                   |
                      |  8   | 0                   |
Error Count(G)        |  1   | 0                   |
                      |  2   | 0                   |
                      |  3   | 0                   |
                      |  4   | 0                   |
                      |  5   | 0                   |
                      |  6   | 0                   |
                      |  7   | 0                   |
                      |  8   | 0                   |
Bit Count(G)          |  1   | 0                   |
                      |  2   | 0                   |
                      |  3   | 0                   |
                      |  4   | 0                   |
                      |  5   | 0                   |
                      |  6   | 0                   |
                      |  7   | 0                   |
                      |  8   | 0                   |
 
show qsfp-dd diagnostics media
Use this command to show QSFP-DD module media side diagnostics information.
Command Syntax
show qsfp-dd PORTNUM diagnostics media
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 diagnostics media
 
Port Number                    : 0
----------------------------------------------------
       Attribute      | Lane |        Value        |
----------------------------------------------------
Signal To Noise Ratio |  1   | 0.00                |
Bit Error Ratio       |  1   | 0.00e+00            |
Bit Error Ratio(G)    |  1   | 0.00e+00            |
Error Count           |  1   | 0                   |
Bit Count             |  1   | 0                   |
Error Count(G)        |  1   | 0                   |
Bit Count(G)          |  1   | 0                   |
show qsfp-dd eeprom
Use this command to show QSFP-DD module EEPROM information.
Command Syntax
show qsfp-dd PORTNUM eeprom
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 eeprom
 
Port Number                   : 0
Identifier                    : QSFP-DD Double Density 8X Pluggable Transceiver
Name                          : SmartOptics
OUI                           : 0x0 0x53 0x4f
Part No                       : SO-TQSFPDD4CCZRP
Revision Level                : A
Serial_Number                 : 214156190
Manufacturing Date            : 220318   (yymmddvv, v=vendor specific)
Module Power Class            : 8
Module Max Power              : 23.75 Watt
Cooling Implemented           : Yes
Module Temperature Max        : 80 Celsius
Module Temperature Min        : 0 Celsius
Operating Voltage Min         : 3.12 Volt
Optical Detector              : PIN
Rx Power Measurement          : Average Power
Tx Disable Module Wide        : No
Cable Assembly Link Length    : Separable Media
Connector Type                : LC (Lucent Connector)
Media Interface Technology    : 1550 nm DFB
CMIS Revision                 : 4.1
Memory Model                  : Paged
MCI Max Speed                 : 1000 kHz
Active Firmware Revision      : 61.20
Inactive Firmware Revision    : 61.20
Hardware Revision             : 49.48
Media Type                    : Optical SMF
Max SMF Link Length           : 630.0 Kilometer
Wavelength Nominal            : 1547.70 nm
Wavelength Tolerance          : 166.55 nm
show qsfp-dd laser grid
Use this command to show QSFP-DD module laser grid spacing information for frequencies of 3.125, 6.25 12.5 25, 33, 50, 75 and 100 GHz.
Command Syntax
show qsfp-dd PORTNUM laser grid (3p125|6p25|12p5|25|33|50|75|100)
Parameters
PORTNUM   
QSFP-DD front panel port number
3p125     
3.125 GHz
6p25      
6.25 GHz
12p5      
12.5 GHz
25        
25 GHz
33        
33 GHz
50        
50 GHz
75        
75 GHz
100       
100 GHz
Default
None.
Command Mode
Exec mode and Privileged Exec mode.
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
show qsfp-dd 0 laser grid 100
 
Port Number          : 0
 
------------------------------------------------------
Channel Number  Frequency (THz) Wavelength (nm)
------------------------------------------------------
        -18      191.300000              1567.133
        -17      191.400000              1566.314
        -16      191.500000              1565.496
        -15      191.600000              1564.679
        -14      191.700000              1563.863
        -13      191.800000              1563.047
        -12      191.900000              1562.233
        -11      192.000000              1561.419
        -10      192.100000              1560.606
        -9       192.200000              1559.794
        -8       192.300000              1558.983
        -7       192.400000              1558.173
        -6       192.500000              1557.363
        -5       192.600000              1556.555
        -4       192.700000              1555.747
        -3       192.800000              1554.940
        -2       192.900000              1554.134
        -1       193.000000              1553.329
        0        193.100000              1552.524
        1        193.200000              1551.721
        2        193.300000              1550.918
        3        193.400000              1550.116
        4        193.500000              1549.315
        5        193.600000              1548.515
        6        193.700000              1547.715
        7        193.800000              1546.917
        8        193.900000              1546.119
        9        194.000000              1545.322
        10       194.100000              1544.526
        11       194.200000              1543.730
        12       194.300000              1542.936
        13       194.400000              1542.142
        14       194.500000              1541.349
        15       194.600000              1540.557
        16       194.700000              1539.766
        17       194.800000              1538.976
        18       194.900000              1538.186
        19       195.000000              1537.397
        20       195.100000              1536.609
        21       195.200000              1535.822
        22       195.300000              1535.036
        23       195.400000              1534.250
        24       195.500000              1533.465
        25       195.600000              1532.681
        26       195.700000              1531.898
        27       195.800000              1531.116
        28       195.900000              1530.334
        29       196.000000              1529.553
        30       196.100000              1528.773
 
show qsfp-dd laser status
Use this command to show QSFP-DD module current laser configuration status and alarm flags.
Command Syntax
show qsfp-dd PORTNUM laser status
Parameters
PORTNUM   
QSFP-DD front panel port number
Default
None.
Command Mode
Exec mode and Privileged Exec mode.
Applicability
This command was introduced in OcNOS version 6.2.0.
Examples
show qsfp-dd 0 laser status
 
Port Number          : 0
 
--------------------------------------------------
       Attribute      | Lane |    Value   | Unit |
--------------------------------------------------
 Grid Spacing         |  1   | 100.000    | GHz  |
 Laser Frequency      |  1   | 191.900000 | THz  |
 Channel Number       |  1   | -12        | --   |
 Wavelength           |  1   | 1562.23    | nm   |
 
-------------------------------------
        Flag        | Lane | Status |
-------------------------------------
 Tuning in progress |  1   | No     |
 Wavelength locked  |  1   | Yes    |
 
-----------------------------------------------
           Flag           | Lane | Status (L) |
-----------------------------------------------
 Target output power OOR  |  1   | No         |
 Fine tuning out of range |  1   | No         |
 Tuning accepted          |  1   | Yes        |
 Channel number valid     |  1   | Yes        |
show qsfp-dd monitors host
Use this command to show QSFP-DD module host side monitors information.
Command Syntax
show qsfp-dd PORTNUM monitors host
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 monitors host
 
Alarm Codes: FDD - FEC Detected Degrade, FED - FEC Excessive Degrade
             LD - Local Degrade, RD - Remote Degrade
             FLOPB - Flexe Loss of Pad Block, FLOMF - Flexe Loss of Multi-Frame
             FLOF - Flexe Loss of Frame, FIIDM - Flexe Instance Id Mismatch
             FCM - Flexe Calendar Mismatch, FIMM - Flexe Instance Map Mismatch
             FGIDM - Flexe GID Mismatch, TLF - Transmit Local Fault
             TRF - Transmit Remote Fault, TLOA - Transmit Loss of Alignment
             RLF - Receive Local Fault, RRF - Receive Remote Fault
             RLOA - Receive Loss of Alignment
 
Port Number                    : 0
-------------------------------------------------
         Flag         | Lane |    Status (L)    |
-------------------------------------------------
Tx LOS                |  1   |  False           |
                      |  2   |  False           |
                      |  3   |  False           |
                      |  4   |  False           |
                      |  5   |  False           |
                      |  6   |  False           |
                      |  7   |  False           |
                      |  8   |  False           |
Tx CDR LOL            |  1   |  False           |
                      |  2   |  False           |
                      |  3   |  False           |
                      |  4   |  False           |
                      |  5   |  False           |
                      |  6   |  False           |
                      |  7   |  False           |
                      |  8   |  False           |
Tx Adaptive Input Eq  |  1   |  Good            |
                      |  2   |  Good            |
                      |  3   |  Good            |
                      |  4   |  Good            |
                      |  5   |  Good            |
                      |  6   |  Good            |
                      |  7   |  Good            |
                      |  8   |  Good            |
 
 
---------------------------------------------------------------------------------
                                Host Performance
---------------------------------------------------------------------------------
           Attribute          | Lane |                 Value                    |
---------------------------------------------------------------------------------
Alarm Status                  |  1   | LD                                       |
---------------------------------------------------------------------------------
 
-----------------------------------------------
                FEC Performance
-----------------------------------------------
       Attribute      | Lane |      Value     |
-----------------------------------------------
Tx Bits               |  1   | 2125037470720  |
Tx Corrected Bits     |  1   | 0              |
Tx Frames             |  1   | 390631888      |
Tx Uncorrected Frames |  1   | 0              |
 
show qsfp-dd monitors media
Use this command to show QSFP-DD module media side monitors information.
Command Syntax
show qsfp-dd PORTNUM monitors media
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 monitors media
 
Alarm Codes: TFIFO - Tx FIFO Error, TLOLDS - Tx Deskew Loss of Lock
             TLOLRC - Tx Reference Clock Loss of Lock, TLOLCMU - Tx CMU Loss of Lock
             TOOA - Tx Out of Alignment, TLOA - Tx Loss of Alignment
             RFIFO - Rx FIFO Error, RLOLDS - Tx Deskew Loss of Lock
             ROOA - Rx Out of Alignment, RLOA - Rx Loss of Alignment
             RLOLCD - Rx Chromatic Dispersion Compensation Loss of Lock
             RLOLD - Tx Demodulator Loss of Lock, RLOM - Rx Loss of Multi Frame
             RLOF - Rx Loss of Frame, FDD - FEC Detected Degrade
             FED - FEC Excessive Degrade, RPF - Remote Phy Fault
             LD - Local Degrade, RD - Remote Degrade
 
Codes: [HA : High Alarm], [LA : Low Alarm], [HW : High Warning], [LW : Low Warning]
 
Port Number                    : 0
----------------------------------------------------------------------------------------------------------------
       Monitors       | Lane |  Value       |  High Alarm  | High Warning | Low Warning  |  Low Alarm   | Unit |
----------------------------------------------------------------------------------------------------------------
Rx Optical Power      |  1   |  -18.9       |  2.0         |  0.0         |  -23.0       |  -28.2       | dBm  |
Tx Optical Power      |  1   |  -7.8        |  0.0         |  -2.0        |  -16.0       |  -18.0       | dBm  |
Tx Bias               |  1   |  287.3       |  0.0         |  0.0         |  0.0         |  0.0         | mA   |
 
-------------------------------------------------
         Flag         | Lane |    Status (L)    |
-------------------------------------------------
Rx LOS                |  1   |  False           |
Tx Failure            |  1   |  False           |
Rx CDR LOL            |  1   |  False           |
 
---------------------------------------------------------------------------------
                                Link Performance
---------------------------------------------------------------------------------
           Attribute          | Lane | Average  | Minimum  | Maximum  |  Unit   |
---------------------------------------------------------------------------------
Rx DSP CCD                    |  1   | -1       | -1       | -1       | ps/nm   |
Rx DSP DGD                    |  1   | 1.00     | 1.00     | 1.00     | ps      |
Rx SOPMD                      |  1   | 40.00    | 40.00    | 40.00    | ps^2    |
Rx PDL                        |  1   | 0.5      | 0.5      | 0.5      | dB      |
Rx OSNR                       |  1   | 36.4     | 36.4     | 36.4     | dB      |
Rx ESNR                       |  1   | 16.4     | 16.4     | 16.4     | dB      |
Rx CFO                        |  1   | 86       | 14       | 158      | MHz     |
Tx Power                      |  1   | -7.77    | -7.78    | -7.76    | dBm     |
Rx Input Optical Power        |  1   | -18.90   | -18.91   | -18.90   | dBm     |
Rx Input Optical Signal Power |  1   | -19.18   | -19.19   | -19.18   | dBm     |
Rx SOPCR                      |  1   | 0        | 0        | 0        | krads/s |
Rx MER                        |  1   | 0.0      | 0.0      | 0.0      | dB      |
---------------------------------------------------------------------------------
Alarm Status                  |  1   | RLOLCD, RLOLD, RPF                       |
---------------------------------------------------------------------------------
 
-----------------------------------------------
                FEC Performance
-----------------------------------------------
       Attribute      | Lane |      Value     |
-----------------------------------------------
Rx Bits               |  1   | 462238792192   |
Rx Corrected Bits     |  1   | 1398045784     |
Rx Frames             |  1   | 902810141      |
Rx Uncorrected Frames |  1   | 0              |
show qsfp-dd monitors module
Use this command to show QSFP-DD module monitors information.
Command Syntax
show qsfp-dd PORTNUM monitors module
Parameters
PORTNUM
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
 
show qsfp-dd 0 monitors module
 
Codes: [HA : High Alarm], [LA : Low Alarm], [HW : High Warning], [LW : Low Warning]
 
Port Number                   : 0
----------------------------------------------------------------------------------------------------------------
Attribute                   | Value        | High Alarm   | High Warning | Low Warning  | Low Alarm    | Units
----------------------------------------------------------------------------------------------------------------
Voltage                     | 3.24         | 3.46         | 3.43         | 3.17         | 3.13         | Volt
Temperature                 | 42.0         | 80.0         | 75.0         | 15.0         | -5.0         | Celsius
TEC Current Magnitude       | 63.000       | 100.00       | 100.00       | -100.00      | -100.00      | %
Laser Temperature           | 43.000       | 80.00        | 75.00        | -40.00       | -80.00       | Celsius
show qsfp-dd state
Use this command to show QSFP-DD module current state information.
Command Syntax
show qsfp-dd PORTNUM state
Parameters
PORTNUM 
QSFP-DD front panel port number
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.1.0.
Example
show qsfp-dd 0 state
 
Port Number                   : 0
Module Fault State            : No fault
Module State                  : Ready
    Data Path State               : Activated [Starting On : Lane-1]
 
tx-input eq-target
Use this command to configure the Tx input equalizer target override value.
Use the  no form of this command to remove the Tx input equalizer target override value.
Command Syntax
tx-input eq-target <1-15>
no tx-input eq-target
Parameters
<1-15> 
Input equalizer target value
Default
None.
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#tx-input eq-target 1
(config-qsfp-dd)#commit
(config-qsfp-dd)#no tx-input eq-target
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 3
(config-qsfp-dd-host)#tx-input eq-target 5
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no tx-input eq-target
(config-qsfp-dd-host)#commit
tx cdr-bypass
Use this command to enable the Tx CDR bypass.
Use the no form of this command to disable the Tx CDR bypass.
Command Syntax
tx cdr-bypass
no tx cdr-bypass
Parameters
None
Command Mode
QSFP-DD and QSFP-DD host-lane modes
Applicability
This command was introduced before OcNOS version 6.5.1.
Example
#configure terminal
(config)#qsfp-dd 0
(config-qsfp-dd)#tx cdr-bypass
(config-qsfp-dd)#commit
(config-qsfp-dd)#no tx cdr-bypass
(config-qsfp-dd)#commit
(config-qsfp-dd)#host-lane 2
(config-qsfp-dd-host)#tx cdr-bypass
(config-qsfp-dd-host)#commit
(config-qsfp-dd-host)#no tx cdr-bypass
(config-qsfp-dd-host)#commit