OcNOS-RON-6.3.1 : System Management Guide : System Management Command Reference : Chassis Management Module Commands : show hardware-information
show hardware-information
Use this command to display hardware information.
Command Syntax
show hardware-information (memory|fan|temperature|led|power (|monitoring-thresholds)|transceiver|system-status|all)
Parameter
all
Hardware details of all modules.
fan
Fan status of the boards.
led
LED status of the boards.
memory
Memory information of the boards.
power
PSU information.
monitoring-thresholds
 
Monitoring thresholds (if provided by hardware).
temperature
Temperature sensor information of the boards.
transceiver
Transceiver presence status and supported list of transceivers.
system-status
System fault status.
Default
None
Command Mode
Exec mode
Applicability
This command was introduced before OcNOS version 1.3. The monitoring-thresholds and system-status parameters were added in OcNOS version 5.2.
Example
#show hardware-information all
-------------------------------------------------------
RAM INFORMATION
-------------------------------------------------------
 
Total : 15930 MB
Used : 1073 MB (7 %)
Free : 14857 MB (93 %)
Shared : 25 MB
Buffers : 153 MB
Total Swap : 0 MB
Free Swap : 0 MB
Current Processes : 253
Total High Memory : 0 MB
Available High Memory : 0 MB
Unit Size : 1 Bytes
Alert Threshold : 90 %
Critical Threshold : 80 %
-------------------------------------------------------
HARD DISK INFORMATION
-------------------------------------------------------
 
Serial Number : 99009190902000000103
Model Number : ATP I-Temp M.2 2242
Firmware Revision : R0822A ATP I-Temp M.2 2242
Cylinders : 16383
Heads : 16
Sectors : 250000000
Unformatted Bytes/Track : 0
Unformatted Bytes/Sector : 0
Revision No : 1008.0
Usage Alert Threshold : 90 %
Usage Critical Threshold : 80 %
----------------------------------------------------------
Filesystem Total Used Free Use%
----------------------------------------------------------
/ 114365 10889 103476 10%
/cfg 476 79 397 17%
/installers 4911 282 4629 6%
----------------------------------------------------------
 
------------------------------------------------System Sensors---------------------------------------------------------
Codes: LNR - Lower Non-Recoverable
LCR - Lower Critical
LNC - Lower Non-Critical
UNC - Upper Non-Critical
UCR - Upper Critical
UNR - Upper Non-Recoverable
Note: For discrete sensor, thresholds and value columns are not applicable.
 
SENSOR | VALUE | UNITS | LNR | LCR | LNC | UNC | UCR | UNR | STATE
--------------------------------------------------------------------------------------------------------------------------
Temp_MAC | 41.000 | degrees C | na | na | na | 96.000 | 101.000 | 106.000 | ok
Temp_CPU | 39.000 | degrees C | na | na | na | 92.000 | 97.000 | 102.000 | ok
Temp_BMC | 33.000 | degrees C | na | na | na | 80.000 | 85.000 | 89.000 | ok
Temp_10GPHY | 35.000 | degrees C | na | na | na | 92.000 | 95.000 | 98.000 | ok
Temp_DDR4 | 31.000 | degrees C | na | na | na | 85.000 | 90.000 | 92.000 | ok
Temp_FANCARD1 | 29.000 | degrees C | na | na | na | 80.000 | 85.000 | 89.000 | ok
Temp_FANCARD2 | 28.000 | degrees C | na | na | na | 80.000 | 85.000 | 89.000 | ok
PSU0_Temp | 38.000 | degrees C | na | na | na | 86.000 | 90.000 | 95.000 | ok
PSU1_Temp | 27.000 | degrees C | na | na | na | 86.000 | 90.000 | 95.000 | ok
VSENSE_BMC_P12V | 12.200 | Volts | 11.200 | 11.400 | na | na | 12.600 | 12.750 | ok
VSENSE_HEATER | 0.000 | Volts | na | na | na | 9.900 | 10.000 | 10.100 | ok
VSENSE_BMC_P2V5 | 2.520 | Volts | 2.320 | 2.360 | na | na | 2.640 | 2.680 | ok
VSENSE_1VDDR | 1.010 | Volts | 0.900 | 0.940 | na | na | 1.060 | 1.080 | ok
VSENSE_BMC_P5VT | 5.040 | Volts | 4.680 | 4.740 | na | na | 5.250 | 5.310 | ok
VSENSE_P5V_SB | 5.010 | Volts | 4.680 | 4.740 | na | na | 5.250 | 5.310 | ok
VSENSE_BMC_1.26V | 1.260 | Volts | 1.150 | 1.200 | na | na | 1.320 | 1.360 | ok
VSENSE_BMC_1.53V | 1.550 | Volts | 1.380 | 1.460 | na | na | 1.610 | 1.690 | ok
VSENSE_BMC_P3V3 | 3.280 | Volts | 3.020 | 3.140 | na | na | 3.480 | 3.640 | ok
FAN_0 | 12400.000 | RPM | 2400.000 | 3200.000 | 6000.000 | na | na | na | ok
FAN_1 | 12500.000 | RPM | 2400.000 | 3200.000 | 6000.000 | na | na | na | ok
FAN_2 | 11600.000 | RPM | 2400.000 | 3200.000 | 6000.000 | na | na | na | ok
FAN_3 | 11900.000 | RPM | 2400.000 | 3200.000 | 6000.000 | na | na | na | ok
FAN_4 | 12200.000 | RPM | 2400.000 | 3200.000 | 6000.000 | na | na | na | ok
PSU0_FAN | 8190.000 | RPM | 3330.000 | 3600.000 | 3960.000 | na | na | na | ok
PSU1_FAN | 0.000 | RPM | 3330.000 | 3600.000 | 3960.000 | na | na | na | Lower Non-Recov
erable
HWM_VCORE_IN | 1.000 | Volts | 0.910 | 0.940 | na | na | 1.060 | 1.090 | ok
HWM_P1V0_VIN | 1.000 | Volts | 0.900 | 0.950 | na | na | 1.050 | 1.070 | ok
HWM_P1V2_VIN | 1.180 | Volts | 1.110 | 1.140 | na | na | 1.260 | 1.290 | ok
HWM_P1V25_VIN | 1.240 | Volts | 1.150 | 1.190 | na | na | 1.310 | 1.340 | ok
HWM_P1V8_VIN | 1.770 | Volts | 1.660 | 1.710 | na | na | 1.900 | 1.950 | ok
HWM_P3V3_VIN | 3.280 | Volts | 3.040 | 3.120 | na | na | 3.480 | 3.580 | ok
HWM_Temp_MAC | 34.000 | degrees C | -45.000 | -42.000 | -40.000 | 86.000 | 90.000 | 95.000 | ok
HWM_Temp_Heater | 39.000 | degrees C | -45.000 | -42.000 | -40.000 | 73.000 | 75.000 | 78.000 | ok
HWM_Temp_BMC | 34.000 | degrees C | -45.000 | -42.000 | -40.000 | 80.000 | 85.000 | 89.000 | ok
HWM_Temp_CPU | 33.000 | degrees C | -45.000 | -42.000 | -40.000 | 86.000 | 90.000 | 95.000 | ok
HWM_Temp_AMB | 28.000 | degrees C | -45.000 | -42.000 | -40.000 | 76.000 | 80.000 | 84.000 | ok
HWM_Temp_PHY3 | 33.000 | degrees C | -45.000 | -42.000 | -40.000 | 86.000 | 90.000 | 95.000 | ok
CPU_PROC_HOT | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
CPU_CAT_ERROR | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
CPU_THERMAL_TRIP | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
CPU_TO_BMC_INT | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
Thermal_NMI | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
Thermal_BMC_ALRT | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
Thermal_PHY_ALRT | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
Thermal_MAC_ALRT | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
Thermal_DDR_ALRT | 0x0 | discrete | na | na | na | na | na | na | Limit Not Excee
ded
CPLD_NMI | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
VCORE_Fault | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
FAN_CARD_INT | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
BMC_LOADDEFAULT | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
CPU_BOOT_Done | 0x0 | discrete | na | na | na | na | na | na | Device Enabled
CPU_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
Fan0_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
Fan1_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
Fan2_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
Fan3_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
Fan4_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
CPU_POWEROK | 0x0 | discrete | na | na | na | na | na | na | Device Enabled
MB_POWEROK | 0x0 | discrete | na | na | na | na | na | na | Device Enabled
PSU0_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
PSU1_Presence | 0x0 | discrete | na | na | na | na | na | na | Device Present
PSU0_POWEROK | 0x0 | discrete | na | na | na | na | na | na | Device Enabled
PSU1_POWEROK | 0x0 | discrete | na | na | na | na | na | na | Device Disabled
PSU0_INT1 | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
PSU1_INT1 | 0x0 | discrete | na | na | na | na | na | na | State Deasserte
d
PSU0_VIN | 118.000 | Volts | na | na | na | na | na | na | ok
PSU0_VOUT | 11.900 | Volts | na | na | na | na | na | na | ok
PSU0_IIN | 0.850 | Amps | na | na | na | na | na | na | ok
PSU0_IOUT | 2.480 | Amps | na | na | na | na | na | na | ok
PSU1_VIN | 0.000 | Volts | na | na | na | na | na | na | ok
PSU1_VOUT | 0.000 | Volts | na | na | na | na | na | na | ok
PSU1_IIN | 0.000 | Amps | na | na | na | na | na | na | ok
PSU1_IOUT | 0.000 | Amps | na | na | na | na | na | na | ok
 
-------------------------------------------------
LED COLOR DESCRIPTION
-------------------------------------------------
POWER GREEN PSU operates Normally
SYSTEM GREEN Normal
GNSS GREEN GNSS in Normal State
SYNCE GREEN Synchronized to external timing source
 
-----------------------------------------------------
Transceiver DDM support list
-----------------------------------------------------
Type :SFP
Vendor Name :FINISAR CORP.
Vendor Part Number :FTLF8519P2BNL
DDM Supported :Yes
 
Type :SFP
Vendor Name :EVERTZ
Vendor Part Number :SFP10G-TR13S
DDM Supported :Yes
 
Type :SFP
Vendor Name :FS
Vendor Part Number :SFP-10GSR-85
DDM Supported :Yes
 
Type :SFP
Vendor Name :FS
Vendor Part Number :SFP-10G-BX40
DDM Supported :Yes
 
Type :SFP
Vendor Name :FS
Vendor Part Number :SFP-10G-BX
DDM Supported :Yes
 
Type :SFP
Vendor Name :FS
Vendor Part Number :SFP-10GZRC-55
DDM Supported :Yes
 
Type :SFP
Vendor Name :FS
Vendor Part Number :SFP-10G-BX80
DDM Supported :Yes
 
Type :SFP
Vendor Name :JDSU
Vendor Part Number :PLRXPLSCS4322N
DDM Supported :Yes
 
Type :SFP
Vendor Name :DELL
Vendor Part Number :CN04HG0091IAA1B
DDM Supported :Yes
 
Type :SFP
Vendor Name :DELL
Vendor Part Number :WTRD1
DDM Supported :Yes
 
Type :SFP
Vendor Name :FINISAR CORP.
Vendor Part Number :FTLF1318P3BTL-FC
DDM Supported :Yes
 
Type :SFP
Vendor Name :DELL
Vendor Part Number :RN84N
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP10G-LRi
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP10G-SRi
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-SX
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-LX
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-EX
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-ZX
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP10G-SR
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP10G-LR
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP10G-ER
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFPP-ER
DDM Supported :Yes
 
Type :SFP28
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP28-SR
DDM Supported :Yes
 
Type :SFP28
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP28-LR
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-SXi
DDM Supported :Yes
 
Type :SFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-SFP1G-LXi
DDM Supported :Yes
 
Type :TSFP
Vendor Name :OCLARO,INC.
Vendor Part Number :TRS7081AHCPA00A
DDM Supported :Yes
 
Type :SFP
Vendor Name :FINISAR CORP.
Vendor Part Number :FTLX8574D3BCL
DDM Supported :Yes
 
Type :SFP
Vendor Name :FINISAR CORP.
Vendor Part Number :FCLF8522P2BTL
DDM Supported :NO
 
Type :SFP
Vendor Name :Edgecore
Vendor Part Number :ET5402-AOC-10M
DDM Supported :Yes
 
Type :SFP
Vendor Name :Hisense
Vendor Part Number :LTE3680P-BH+
DDM Supported :Yes
 
Type :SFP
Vendor Name :Hisense
Vendor Part Number :LTF5308B-BHA+
DDM Supported :Yes
 
Type :SFP
Vendor Name :Hisense
Vendor Part Number :LTF7226B-BHA+
DDM Supported :Yes
 
Type :QSFP
Vendor Name :AVAGO
Vendor Part Number :AFBR-79E4Z
DDM Supported :Yes
 
Type :QSFP
Vendor Name :FINISAR CORP
Vendor Part Number :FCCN410QD3C
DDM Supported :Yes
 
Type :QSFP
Vendor Name :FINISAR CORP
Vendor Part Number :FTL410QE4C
DDM Supported :Yes
 
Type :QSFP
Vendor Name :DELL
Vendor Part Number :119N6
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFP85P1040PD000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFPQL010400D000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFPQL010400B000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFPQL002400D000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFP85P3040PD000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFP85P1040PB000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQC504000000
DDM Supported :NO
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM014000000
DDM Supported :NO
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM034000000
DDM Supported :NO
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM054000000
DDM Supported :NO
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFP1301040PD000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :Skylane Optics
Vendor Part Number :QFPQL040400D000
DDM Supported :Yes
 
Type :QSFP
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :IPIENQSFP40GSR4
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :DELL
Vendor Part Number :4WJ41
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :FINISAR CORP
Vendor Part Number :FCBN425QE1C
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :FINISAR CORP.
Vendor Part Number :FTLC1151RDPL
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :FINISAR CORP
Vendor Part Number :FTLC9551REPM
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :INPHI CORP
Vendor Part Number :IN-Q2AY2
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :FS
Vendor Part Number :QSFP28-SR4-100G
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :FS
Vendor Part Number :QSFP-PC03
DDM Supported :NO
 
Type :QSFP28
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-QSFP28-SR4
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :EN-QSFP28-LR4
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD010C07D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q2885P30C0PF000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD020C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM01C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM02C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM03C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM05C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM07C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM10C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM20C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQM30C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAOQQP10C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q2885P10C0PF000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD040C00F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD010C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD010C04D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD040C05F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD040C05D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM03C000000
DDM Supported :NO
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM01C000000
DDM Supported :NO
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM02C000000
DDM Supported :NO
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQM05C000000
DDM Supported :NO
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :DAPQQC50C000000
DDM Supported :NO
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QL002C00F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q2C31002C00F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q2C31P50C00F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q2B85M70C00D000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :Skylane Optics
Vendor Part Number :Q28QD080C05F000
DDM Supported :Yes
 
Type :QSFP28
Vendor Name :E.C.I.NETWORKS
Vendor Part Number :IPIENQSFP28SR4
DDM Supported :Yes
 
 
TX : Transmit status
RX-Los : Receive status
RESET : Normal (Out of reset), Reset (In reset)
POWER : Power level Low/High
- : NotApplicable
 
SFP:[0-27]
----------------------------------------------
PORT PRESENCE Tx Rx-Los
----------------------------------------------
0 Not Present Off -
1 Not Present Off -
2 Not Present Off -
3 Present On -
4 Present On -
5 Not Present Off -
6 Present On -
7 Present On Off
8 Not Present Off -
9 Not Present Off -
10 Present On -
11 Present On -
12 Present On On
13 Not Present Off -
14 Not Present Off -
15 Present On Off
16 Present On Off
17 Not Present Off -
18 Present On -
19 Present On Off
20 Present On Off
21 Not Present Off -
22 Present On -
23 Present On -
24 Not Present Off -
25 Not Present Off -
26 Not Present Off -
27 Not Present Off -
 
QSFP:[0-1]
--------------------------------------------------------------------------------------------
PORT PRESENCE RESET POWER LANE
--------------------------------------------------------------------------------------------
1 2 3 4
--------------------------------------------------------------------------------------------
0 Not Present Reset Low Tx off off off off
Rx-Los Off Off Off Off
Tx-Los Off Off Off Off
1 Present Normal High Tx on on on on
Rx-Los Off Off Off Off
Tx-Los Off Off Off Off
 
System Over all status : Normal
 
---------------------------
Components status
---------- ----------------
CPU : Normal
RAM : Normal
DISK : Normal
SOFTWARE : Normal
 
Codes: H-Mi- High Minor H-Ma- High Major L-Mi- Low Minor L-Ma- Low Major
 
Component Fault Timestamp Thresh Violation-Status
--------- ----- --------- ------ ----------------
 
Table 25-65 explains the show command output fields.
 
Table 25-65: show hardware-information all output
Field
Description
Ram Information
Used memory, free memory, shared, buffers, total swap, and free swap memory.
Hard Disk Information
Hard drive serial number, model, firmware revision, cylinders, heads, and sectors, as well as revision number and total size.
Fans
Fan tray numbers, numbers of fans per tray, and their speed in RPM.
Board Temp Sensors Temperature
Sensor type, current temperature, and operating range.
BCM Chip Internal Temperature
Broadcom chip current internal temperature, Operating range and average temperature.
System Power Information
System power Information. Shows Voltage on all rails, and whether the power is up or has failed.
PSU
Main power supply statistics: Volts in, volts out, current in and out amperes, power in and out in watts, temperature of each power supply, and fan speed in RPM.
LED
What the LEDs represent, what state the LEDs mean, and a description of what the LEDs current color means.
Transceiver DDM support list
Transceivers: type, vendor name, part number, and whether Digital Diagnostic Monitoring (DDM) is supported.
Port Number
Port numbers, port type (SFP, QSFP, etc) and whether a transceiver is in the port.
 
#show hardware-information power
-----------------------------------------------------
Hardware Thresholds
-----------------------------------------------------
PSU1 [Input Voltage]
-----------------------------
Shutdown(O) : 62.00 Volts
Resume(O) : 60.00 Volts
Shutdown(U) : 38.00 Volts
Resume(U) : 36.00 Volts
PSU1 [Temperature 1]
-----------------------------
Shutdown(O) : 85.00 Celsius
Resume(O) : 80.00 Celsius
PSU2 [Input Voltage]
-----------------------------
Shutdown(O) : 62.00 Volts
Resume(O) : 60.00 Volts
Shutdown(U) : 38.00 Volts
Resume(U) : 36.00 Volts
 
-----------------------------------------------------
System Power Information
-----------------------------------------------------
CMM_PS1_12V_PG : FAIL
CMM_PS2_12V_PG : GOOD
CMM_PS1_AC_ALERT : FAIL
CMM_PS2_AC_ALERT : GOOD
 
Codes: * Not Supported by device NA Not Applicable O Over U Under
 
PSU VOLT-IN VOLT-OUT CURR-IN CURR-OUT PWR-IN PWR-OUT TEMP-1 TEMP-2 FAN-1 FAN-2 PWR_
OUT_MAX
(Volt) (Volt) (Ampere) (Ampere) (Watt) (Watt) (Celsius) (Celsius) (Rpm) (Rpm)
-----------------------------------------------------------------------------------------------------------------------------
------
2 225.00 12.00 1.47 25.50 330.00 306.00 27.00 31.00 4512 NA* NA*
 
#
 
Table 25-66 explains the show hardware-information power command output fields.
 
Table 25-66: show hardware-information power output fields 
Field
Description
PSU Input Voltage
Shutdown and resume over and under voltages
PSU Temperature
Shutdown and resume over temperatures
System Power Information
Overall status of each PSU
PSU
Power supply unit identifier
VOLT-IN
Input voltage
VOLT-OUT
Output voltage
CURR-IN
Input current (ampere)
CURR-OUT
Output current (ampere)
PWR-IN
Input power (watts)
PWR-OUT
Output power (watts)
TEMP-1
Temperature (Celsius)
TEMP-2
Temperature (Celsius)
FAN-1
FAN 1 RPM
FAN-2
FAN 2 RPM
PWR_OUT_MAX
Power out maximum
 
#show hardware-information power monitoring-thresholds
-----------------------------------------------------
Input Voltage [PSU1]
-----------------------------------------------------
High Alarm : 60.00 Volts
Low Alarm : 40.00 Volts
High Warning : 58.00 Volts
Low Warning : 42.00 Volts
-----------------------------------------------------
Temperature 1 [PSU1]
-----------------------------------------------------
High Alarm : 75.00 Celsius
Low Alarm : -10.00 Celsius
High Warning : 73.00 Celsius
Low Warning : -8.00 Celsius
-----------------------------------------------------
Input Voltage [PSU2]
 
-----------------------------------------------------
High Alarm : 60.00 Volts
Low Alarm : 40.00 Volts
High Warning : 58.00 Volts
Low Warning : 42.00 Volts
 
Table 25-67 explains the show hardware-information power monitoring-thresholds command output fields.
 
Table 25-67:  show hardware-information power monitoring-thresholds output fields
Field
Description
Input Voltage
Voltages for high alarm, low alarm, high warning, and low warning thresholds
Temperature
Temperatures for high alarm, low alarm, high warning, and low warning thresholds
 
#show hardware-information system-status
 
System Over all status : Normal
 
---------------------------
 
Components status
 
---------- ----------------
 
CPU : Normal
 
RAM : Normal
 
DISK : Normal
 
FAN : Normal
 
POWER : Normal
 
SOFTWARE : Normal
 
Codes: H-Mi- High Minor H-Ma- High Major L-Mi- Low Minor L-Ma- Low Major
 
Component Fault Timestamp Thresh Violation-Status
 
--------- ----- --------- ------ ----------------
 
DISK H-Mi 12-02-2021 18:39:32 > 80.00 84.00%
 
POWER L-Mi 12-02-2021 18:43:46 < 42.00 Psu [1] of VOLT-IN is 42.00
 
12-02-2021 18:42:35 Psu [2] of VOLT-IN is 42.00
 
L-Ma 12-02-2021 18:41:44 < 40.00 Psu [1] of VOLT-IN is 24.00
 
H-Ma 12-02-2021 18:44:27 > 75.00 Psu [1] of TEMP1 is 80.00
 
#
Table 25-68 explains the show hardware-information system-status command output fields.
 
Table 25-68: show hardware-information system-status output fields 
Field
Description
System Over all status
Self explantory
Components status
Status of CPU, RAM, disk, fan, power, and software
Component
Component name
Fault
Type of fault:
H-Mi- High Minor
H-Ma- High Major
L-Mi- Low Minor
L-Ma- Low Major
Timestamp
Date and time of the faullt
Thresh
Threshold limit
Violation-Status
Explanation of violation
Last modified date: 07-14-2023