OcNOS-RON-6.3.1 : System Management Guide : System Management Command Reference : Digital Diagnostic Monitoring Commands : show interface transceiver details
show interface transceiver details
Use this command to display details of transceivers and threshold violations.
Command Syntax
show interface (IFNAME|) transceiver (detail|threshold violation|)
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers.
detail
Transceiver information such as voltage, temperature, power, and current.
threshold violation
 
Transceiver threshold violations.
Default
None
Command Mode
Exec mode
Applicability
This command was introduced before OcNOS version 1.3.
Example
#show interface transceiver detail
PORT Temp High Alarm High Warn Low Warn Low Alarm
(Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
 
--------------------------------------------------------
5 30.060 95 90 -20 -25
6 30.463 95 90 -20 -25
52 34.486 75 70 0 -5
53 30.764 75 70 0 -5
 
Voltage High Alarm High Warn Low Warn Low Alarm
(Volts) (Volts) (Volts) (Volts) (Volts)
---------------------------------------------------------
5 3.339 3.900 3.700 2.900 2.700
6 3.365 3.900 3.700 2.900 2.700
52 3.360 3.630 3.465 3.135 2.970
53 3.353 3.630 3.465 3.135 2.970
 
Current High Alarm High Warn Low Warn Low Alarm
(mA) (mA) (mA) (mA) (mA)
---------------------------------------------------------
5 6.468 17.000 14.000 2.000 0.034
6 7.014 17.000 14.000 2.000 0.034
52 7.250 10.000 9.500 1.000 0.500
53 7.284 10.000 9.500 1.000 0.500
 
RxPower High Alarm High Warn Low Warn Low Alarm
(dBm) (dBm) (dBm) (dBm) (dBm)
---------------------------------------------------------
5 0.332 1.259 0.794 0.016 0.010
6 0.321 1.259 0.794 0.016 0.010
52 0.727 2.188 1.738 0.112 0.000
53 0.352 2.188 1.738 0.112 0.000
 
TxPower High Alarm High Warn Low Warn Low Alarm
(mW) (mW) (mW) (mW) (mW)
---------------------------------------------------------
5 0.342 0.631 0.631 0.079 0.067
6 0.342 0.631 0.631 0.079 0.067
Table 26-76 explains the output fields.
 
Table 26-76: show interface transceiver details output
Field
Description
Port
The number of the transceiver port.
Temp
Temperature in degrees Celsius of the transceiver.
Voltage
Voltage in Volts on the transceiver.
Current
Current in Milliamperes used by the transceiver.
Rx Power
Power received in Decibel-milliwatts (dBm) by the transceiver.
Tx Power
Power being transmitted in milliWatts by the transceiver.
High Alarm
The level that is needed to be reached to trigger a high alarm.
High Warn
The level that is needed to be reached to trigger a high warning.
Low Warn
The level that is needed to be reached to trigger a low warning.
Low Alarm
The level that is needed to be reached to trigger a low alarm.
 
Last modified date: 07-14-2023