OcNOS-RON : System Management Guide : System Management Configuration Guide : Fault Management System Configuration : Alarm Descriptions
Alarm Descriptions
Table 34-5 describes the supported alarms.
Table 34-5: FMS alarms 
Alarm
Description
CMM_DDM_MONITOR_CURRENT
Transceiver Bias Current crossed the threshold limit
CMM_DDM_MONITOR_FREQ
Transceiver Frequency crossed the threshold limit
CMM_DDM_MONITOR_RxPOWER
Transceiver Rx Power crossed the threshold limit
CMM_DDM_MONITOR_TEC
Transceiver Thermoelectric Cooler fault
CMM_DDM_MONITOR_TEMP
Transceiver Temperature crossed the threshold limit
CMM_DDM_MONITOR_TxPOWER
Transceiver TX Power crossed the threshold limit
CMM_DDM_MONITOR_VOLT
Transceiver Voltage crossed the threshold limit
CMM_DDM_MONITOR_WAVE
Transceiver Wavelength crossed the threshold limit
CMM_FAN_CTRL
Fan insertion, removal, speed, or fault condition alarm
CMM_MONITOR_CPU
CPU load average crossed the threshold limit
CMM_MONITOR_CPU_CORE
CPU core usage crossed the threshold limit
CMM_MONITOR_DISK_READ_ACTIVITY
Disk read activity crossed the threshold limit
CMM_MONITOR_DISK_REMAIN_LIFE
Disk remaining life crossed the threshold limit
CMM_MONITOR_DISK_WRITE_ACTIVITY
Disk write activity crossed the threshold limit
CMM_MONITOR_PSU_POWER
Power supply unit insertion, removal, or fault condition
CMM_MONITOR_PSU_IIN
Power supply unit input current crossed the threshold limit
CMM_MONITOR_PSU_IOUT
Power supply unit output current crossed the threshold limit
CMM_MONITOR_PSU_PIN
Power supply unit input power crossed the threshold limit
CMM_MONITOR_PSU_POUT
Power supply unit output power crossed the threshold limit
CMM_MONITOR_PSU_PRESENCE
Power supply unit is present
CMM_MONITOR_PSU_TEMP1
Power supply unit temperature 1 crossed the threshold limit
CMM_MONITOR_PSU_TEMP2
Power supply unit temperature 2 crossed the threshold limit
CMM_MONITOR_PSU_VIN
Power supply unit input voltage crossed the threshold limit
CMM_MONITOR_PSU_VOUT
Power supply unit output voltage crossed the threshold limit
CMM_MONITOR_RAM
RAM memory usage crossed the threshold limit
CMM_MONITOR_SDCARD
Hard-disk usage crossed the threshold limit or fault condition
CMM_MONITOR_TEMP
Temperature sensor crossed the threshold limit
CMM_TAI_CD_ALARM
RX lane current chromatic dispersion crossed the threshold limit
CMM_TAI_CD_CLEAR
RX lane current chromatic dispersion recovered from the threshold
CMM_TAI_Q_MARGIN_ALARM
Network RX Q-margin over PM interval value crossed threshold limit
CMM_TAI_Q_MARGIN_CLEAR
Network RX Q-margin over PM interval value recovered from the threshold
CMM_TAI_RX_LOS
RX-Loss-Of-Signal alarm Detected
CMM_TAI_RX_LOS_CLEAR
RX-Loss-Of-Signal alarm Cleared
CMM_TAI_SNR_ALARM
Network lane0 current Signal-to-Noise Ratio crossed threshold limit
CMM_TAI_SNR_CLEAR
Network lane0 current Signal-to-Noise Ratio recovered from the threshold
CMM_TRANSCEIVER
Transceiver on fault condition
IFMGR_IF_DOWN
Interface state down
IFMGR_IF_UP
Interface state up
CMM_MONITOR_FAN
FAN monitoring - crossed the threshold limit
CMM_MONITOR_CURRENT
Current crossed the threshold limit
CMM_MONITOR_VOLTAGE
Voltage crossed the threshold limit
 
Last modified date: 08/28/2023