Smart SFP Commands
This chapter is a reference for the Smart SFP commands:
ddm raise
Use this command to raise a false alarm on the remote smart SFP.
Use this command to clear the false alarm on the remote smart SFP.
Command Syntax 
ddm raise false alarm IFNAME (((temperature|voltage|voltage2|current|rxpower|txpower|frequency-error|wavelength-error|snr|resisi|leveltrans|teccurrent|prefecber|
  uncorrectedber|lasertemp) VALUE)| tec-fault) (remote|)
no ddm raise false alarm IFNAME (temperature|voltage|voltage2|current|rxpower|txpower|frequency-error|wavelength-error|tec-fault|snr|resisi|leveltrans|teccurrent|prefecber|
uncorrectedber|lasertemp) (remote|)
Parameters
None
Default 
By default, the debug command is not configured.
Command Mode
Configuration mode 
Applicability
This command was introduced before OcNOS version 6.2.0.
Example
The following command displays detailed information ddm raise.
OcNOS(config)#conf t
OcNOS(config)#ddm raise false alarm xe1 temperature +95.00 remote
OcNOS(config)#ddm raise false alarm xe1 voltage +3.50 remote
 
 
show interface controller details
Use this command to display the EEPROM details.
Command Syntax 
show interface (IFNAME|) controllers (remote)
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers. 
remote
Interface name
Default 
None
Command Mode
Exec mode
Applicability
This command was introduced in OcNOS version 6.2.0 
Example
The following command displays detailed information of smart SFP.
 
OcNOS#show interface controllers remote
Codes: SMF - Single Mode Fiber, MMF - Multi Mode Fiber, FC - Fiber Channel
       OM1 - 62.5 Micron MMF [200MHzkm @ 850nm & 500MHzkm @ 1310nm]
       OM2 - 50 Micron MMF [500MHzkm @ 850nm & [500MHzkm @ 1310nm]
       OM3 - 50 Micron MMF [2000MHz*km @ 850nm], OUI - Vendor ID
       OM4 - 50 Micron MMF [4700MHz*km @ 850nm], BR - Bit Rate, CC - Check Code
       AOC - Active Optical Cable, ACC -  Active Copper Cable, PC - Power Class
       CDR - Clock Data Recovery, CLEI - Common Language Equipment Identification
       LR - Long Reach, SR - Short Reach, IR - Intermediate Reach
       CCA - Copper Cable Attenuation
 
############################################################
Port Number                   : 24
Name                          : WTD
OUI                           : 0x0 0x1c 0xad
Part No                       : RTXM330-8921
Serial_Number                 : ME223702430001
Identifier                    : SFP/SFP+/SFP28
Ext. Identifier               : GBIC/SFP Is Defined By Two-Wire Interface ID Only
Connector Type                : LC (Lucent Connector)
Ethernet/Ext-Eth Compliance   : 100GBASE-LR4 or 25GBASE-LR
SONET Compliance              :
Infiniband Compliance         :
ESCON Compliance              :
FCLink Length                 :
FC Technology                 :
FC Transmission Media         :
FC Speed                      :
SFP+ Cable Technology         :
Length SMF                    : 10 (Kilometers)
Length SMF                    : 100 (X 100 Meters)
Length OM1                    : 0 (X 10 Meters)
Length OM2                    : 0 (X 10 Meters)
Length OM3                    : 0 (X 10 Meters)
Length OM4                    : 0 (X 10 Meters)
Revision Level                : V01
Wavelength                    : 1269nm
Manufacturing Date            : 220809   (yymmddvv, v=vendor specific)
Encoding Algorithm            : 64B/66B
CC                            : 0x25
CC Ext.                       : 0x68
Nominal BR                    : 255 (X 100 MBd)
Max BR                        : 103
Min BR                        : 0
Options Implemented           : Power Level 3
                                Paging
                                Internal Re-Timer Or CDR
                                Cooled Laser Trasnmitter
                                Power Level 2
                                RATE_SELECT
                                TX_DISABLE
                                TX_FAULT
                                Rx Loss Of Signal (LOS)
DDM Support                   : Yes
  
show interface transceiver details
Use this command to display details of transceivers and threshold violations.
Command Syntax 
show interface (IFNAME|) transceiver (detail|threshold violation|(protocol (stats|))|)(remote|)
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers.
detail
Transceiver information such as voltage, temperature, power, and current.
threshold violation
 
Transceiver threshold violations.
Codes           
 
* Not Qualified By IP Infusion,  ** Not Supported By Module.
Default 
None
Command Mode
Exec mode
Applicability
This command was introduced before OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver details.
OcNOS#sh int transceiver detail
Codes:  * Not Qualified By IP Infusion,  ** Not Supported By Module,  -- No Power,  - Not Applicable
 
 
Intf       DDM        Temp       AlertMax   CritMax    CritMin    AlertMin
                      (Celsius)  (Celsius)  (Celsius)  (Celsius)  (Celsius)
---------------------------------------------------------------------------
 
ce0        Active*    +22.52     +85.00     +80.00     -5.00      -10.00
ce2        Active     +20.32     +75.00     +70.00     +0.00      -5.00
xe4        Active*    +23.62     +95.00     +85.00     -40.00     -50.00
xe5        Active*    +19.79     +100.00    +95.00     -35.00     -40.00
xe16       Active*    +25.84     +95.00     +85.00     -10.00     -50.00
xe26       Active     +19.01     +95.00     +90.00     -20.00     -25.00
 
 
 
Intf       DDM        Volt       AlertMax   CritMax    CritMin    AlertMin
                      (Volts)    (Volts)    (Volts)    (Volts)    (Volts)
---------------------------------------------------------------------------
ce0        Active*    +3.314     +3.600     +3.500     +3.100     +2.900
ce2        Active     +3.260     +3.630     +3.465     +3.135     +2.970
xe4        Active*    +3.260     +3.600     +3.500     +3.100     +3.000
xe5        Active*    +3.253     +3.600     +3.500     +2.900     +2.800
xe16       Active*    +3.284     +3.630     +3.500     +3.030     +2.930
xe26       Active     +3.289     +3.900     +3.700     +2.900     +2.700
 
 
Intf       DDM        Lane       Curr       AlertMax   CritMax    CritMin    AlertMin
                                 (mA)       (mA)       (mA)       (mA)       (mA)
-------------------------------------------------------------------------------------
ce0        Active*    1          +6.114     +15.000    +12.000    +2.000     +0.000
                      2          +6.120     +15.000    +12.000    +2.000     +0.000
                      3          +6.110     +15.000    +12.000    +2.000     +0.000
                      4          +6.116     +15.000    +12.000    +2.000     +0.000
ce2        Active     1          +7.464     +13.000    +11.000    +5.000     +3.000
                      2          +7.540     +13.000    +11.000    +5.000     +3.000
                      3          +7.444     +13.000    +11.000    +5.000     +3.000
                      4          +7.474     +13.000    +11.000    +5.000     +3.000
xe4        Active*    -          +6.100     +110.000   +100.000   +1.000     +1.000
xe5        Active*    -          +7.552     +15.000    +13.000    +2.000     +1.000
xe16       Active*    -          +5.800     +15.000    +12.000    +3.000     +2.000
xe26       Active     -          +7.050     +17.000    +14.000    +2.000     +1.000
 
 
 
Intf       DDM        Lane       RxPwr      AlertMax   CritMax    CritMin    AlertMin
                                 (dBm)      (dBm)      (dBm)      (dBm)      (dBm)
-------------------------------------------------------------------------------------
ce0        Active*    1          -0.185     +4.400     +3.400     -13.298    -14.306
                      2          +0.342     +4.400     +3.400     -13.298    -14.306
                      3          +0.396     +4.400     +3.400     -13.298    -14.306
                      4          -2.927     +4.400     +3.400     -13.298    -14.306
ce2        Active     1          +1.302     +3.400     +2.400     -11.002    -14.001
                      2          +1.486     +3.400     +2.400     -11.002    -14.001
                      3          +1.581     +3.400     +2.400     -11.002    -14.001
                      4          +1.594     +3.400     +2.400     -11.002    -14.001
xe4        Active*    -         -1.890     +2.500     +0.500     -14.401    -16.402
xe5        Active*    -         -40.000    +3.000     +0.000     -13.002    -16.003
xe16       Active*    -           --       +2.000     +1.000     -14.401    -16.402
xe26       Active     -         -5.933     +1.000     -1.002     -18.013    -20.000
 
Intf       DDM        Lane       TxPwr      AlertMax   CritMax    CritMin    AlertMin
                                 (dBm)      (dBm)      (dBm)      (dBm)      (dBm)
-------------------------------------------------------------------------------------
ce0        Active*    1         -0.085     +4.400     +3.400     -9.201     -10.205
                      2         -0.161     +4.400     +3.400     -9.201     -10.205
                      3         +0.217     +4.400     +3.400     -9.201     -10.205
                      4         +0.204     +4.400     +3.400     -9.201     -10.205
ce2        Active     1         +0.297     +5.000     +3.000     -8.000     -10.000
                      2         -0.078     +5.000     +3.000     -8.000     -10.000
                      3         +0.131     +5.000     +3.000     -8.000     -10.000
                      4         +0.323     +5.000     +3.000     -8.000     -10.000
xe4        Active*    -         -1.316     +2.500     +0.500     -8.199     -10.200
xe5        Active*    -         -2.299     +1.000     +0.000     -7.001     -8.000
xe16       Active*    -         -1.000     +2.500     +2.000     -8.199     -10.200
xe26       Active     -         -4.441     -2.000     -2.000     -11.024    -11.739
 
Intf       DDM        Lane       Freq-Err   AlertMax   CritMax    CritMin    AlertMin
                                 (GHz)      (GHz)      (GHz)      (GHz)      (GHz)
-------------------------------------------------------------------------------------
 
Intf       DDM        Lane       Wave-Err   AlertMax   CritMax    CritMin    AlertMin
                                 (nm)       (nm)       (nm)       (nm)       (nm)
-------------------------------------------------------------------------------------
 
Intf       DDM        Lane       Tx         Rx-LOS     Tx-LOS
------------------------------------------------------------------------------
ce0        Active*    1          On         Off        Off
                      2          On         Off        Off
                      3          On         Off        Off
                      4          On         Off        Off
ce2        Active     1          On         Off        Off
                      2          On         Off        Off
                      3          On         Off        Off
                      4          On         Off        Off
xe4        Active*    -          On         Off        -
xe5        Active*    -          On         On         -
xe9        Inactive*  -          On         On         -
xe11       Inactive*  -          On         On         -
xe13       Inactive*  -          On         On         -
xe14       Inactive*  -          On         On         -
xe16       Active*    -          On         On         -
xe26       Active     -          On         Off  
 
 
Table 11-58 explains the output fields.
  
Table 11-58: show interface transceiver details output
Field  | Description  | 
|---|
Port  | The number of the transceiver port.  | 
Temp  | Temperature in degrees Celsius of the transceiver.  | 
Voltage  | Voltage in Volts on the transceiver.  | 
Current  | Current in Milliamperes used by the transceiver.  | 
Rx Power  | Power received in Decibel-milliwatts (dBm) by the transceiver.  | 
Tx Power  | Power being transmitted in milliWatts by the transceiver.  | 
High Alarm  | The level that is needed to be reached to trigger a high alarm.  | 
High Warn  | The level that is needed to be reached to trigger a high warning.  | 
Low Warn  | The level that is needed to be reached to trigger a low warning.  | 
Low Alarm    | The level that is needed to be reached to trigger a low alarm.   | 
Codes *  | Not Qualified By IP Infusion, ** Not Supported By Module  | 
show interface transceiver detail remote
Use this command to display all the threshold values for volt, temperature, and power for the remote transceiver.
Command Syntax 
show interface (IFNAME|) transceiver detail remote
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers.
remote
Interface name
detail
Remote transceivers information
Default 
None.
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver detail remote.
OcNOS#show interface transceiver detail remote
 
      Intf       DDM        Temp       AlertMax   CritMax    CritMin    AlertMin
                            (Celsius)  (Celsius)  (Celsius)  (Celsius)  (Celsius)
      ---------------------------------------------------------------------------
 
      Intf       DDM        Volt       AlertMax   CritMax    CritMin    AlertMin
                            (Volts)    (Volts)    (Volts)    (Volts)    (Volts)
--------------------------------------------------------------------------
show interface transceiver protocol
Use this command to display the OAM protocol status and module status of the local module.
Command Syntax 
show interface (IFNAME|) transceiver protocol
Parameters
IFNAME
Interface name. If not specified, this command displays details for all connected transceivers.
protocol
OAM protocol status, and module status of local module.
Default 
None.
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver protocol.
OcNOS#show interface transceiver protocol
 
      ############################################################
      Port Number                   : 2
      OAM status                    : On
      Local status                  : Link failure
show interface transceiver protocol remote
Use this command to display the OAM protocol status and module status of the remote module.
Command Syntax 
show interface (IFNAME|) transceiver protocol remote
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers.
protocol
OAM protocol status, and module status of the remote module.
remote
Remote transceiver information
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver protocol remote.
OcNOS#show interface transceiver protocol remote
 
      ############################################################
      Port Number                   : 2
      Remote status                 : Remote TCVR Ready
show interface transceiver protocol stats
Use this command to display the protocol frame statistics.
Command Syntax 
show interface (IFNAME|) transceiver protocol stats
Parameters
IFNAME
Interface name. If not specified, this command displays details for all connected transceivers.
protocol
OAM protocol status,  and module status of local module.
stats
Protocol frame statistics
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver protocol stats
OcNOS#show interface transceiver protocol stats
 
      ############################################################
      Port Number                   : 2
      OAM frames Sent               : 1583
      OAM frames received corretly  : 1
      OAM frames received with error: 2
show interface transceiver remote
Use this command to display the remote transceiver information.
Command Syntax 
show interface (IFNAME|) transceiver remote
Parameters
IFNAME
Interface name. If not specified, this command displays details for all connected transceivers.
remote
Remote transceiver information.
 
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver remote
OcNOS#show interface transceiver remote
 
      Intf       DDM        Temp       Voltage    Lane       Tx         Rx-Los     Tx-
      Los     Current    TxPower    RxPower    Freq-Err   Wave-Err
                           (Celsius)  (volt)
              (mA)       (dBm)      (dBm)      (GHZ)      (nm)
      --------------------------------------------------------------------------------
      ---------------------------------------------------------------
show interface transceiver threshold violations remote
Use this command to display the details of remote transceivers and threshold violations.
Command Syntax 
show interface (IFNAME|) transceiver (detail|threshold violation|) remote
Parameters
IFNAME
              Interface name. If not specified, this command displays details of all connected    
              transceivers.
detail
             Transceiver information, such as voltage, temperature, power, and current.
threshold violation
     Transceiver threshold violations.
 
              
 
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of interface transceiver threshold violations remote.
OOcNOS#show interface transceiver threshold violations remote
       Intf       Lane       Timestamp            Type of alarm
       ----       ----       ---------            -------------
 
xcvr <IFNAME> tx-disable <1-256> remote
Use this command to laser off the remote transceiver for <1-256> seconds and to turn the laser ON.
Command Syntax 
xcvr <IFNAME> tx-disable <1-256> remote
Parameters
IFNAME     
        Interface name.
remote             
Remote transceiver.
 
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of xcvr <IFNAME> tx-disable <1-256> remote.
 OcNOS#xcvr xe2 tx-disable 2 remote 
xcvr <IFNAME> reset remote
Use this command to reset the remote transceiver.
Command Syntax 
xcvr <IFNAME> reset remote
Parameters
IFNAME     
        Interface name.
remote             
Remote transceiver.
reset
         Reset remote transceiver
Default 
None
Command Mode
Exec mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of xcvr <IFNAME> reset remote.
  OcNOS#xcvr xe2 reset remote
 
xcvr loopback
Use this command to loopback Tx and Rx Input loop back for remote.
Use this command to loopback Tx and Rx Output loop back for remote.
Command Syntax 
xcvr loopback (in|out) remote 
no xcvr loopback (in|out) remote
 
Parameters
None
Default 
None
Command Mode
Interface mode 
Applicability
This command was introduced in OcNOS version 6.2.0.
Example
The following command displays detailed information of xcvr loopback.
	     OcNOS(config)#int xe2
     OcNOS(config-if)#xcvr loopback in remote
     OcNOS(config-if)#commit
     OcNOS(config-if)#end
     OcNOS#conf t
     OcNOS(config)#int xe2
     OcNOS(config-if)#xcvr loopback out remote
     OcNOS(config-if)#commit
     OcNOS(config-if)#end