show ethernet cfm errors
Use this command to verify the defects present in a MEP.
Command Syntax
show ethernet cfm errors (domain DOMAIN_NAME) 
Parameters
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm errors domain 12345 
Domain Name      Level     Vlan      MEPID      Defects 
-------------------------------------------------------- 
12345             7        10        100        .....
 
 
Table 1-4 explains the output fields
 Table 1-4: show ethernet cfm errors 
Field  | Description  | 
|---|
Domain Name  | Maintenance Domain name  | 
Level  | MD Level  | 
Vlan  | Vlan identifier  | 
MEPID  | Maintenance End Point identifier  | 
Defects  | Defects in current MEP  | 
 
Last modified date: 07/11/2023