show ethernet cfm maintenance-points remote
Use this command to display information about a remote MEP.
Command Syntax
show ethernet cfm maintenance-points remote (mpid MEP_ID|) (domain DOMAIN_NAME)(ma-name MA_NAME) 
Parameters
MEP_ID
Remote MEP identifier <1-8191>
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
MA name
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm maintenance-points remote domain 12345 
MEPID	RMEPID	LEVEL	VLAN	Rx CCM	RDI	PEER-MAC	TYPE
 
100	200	7	10	Yes	False	a82b.b579.fd2a	Configured
 
Table 1-11 explains the output fields. 
 Table 1-11: show ethernet cfm maintenance-points remote
Field  | Description  | 
|---|
MEPID  | MEP identifier  | 
RMEPID  | Remote MEP identifier  | 
LEVEL  | MD level  | 
VLAN  | VLAN identifier  | 
Rx CCM  | Yes if CCM receives, no if CCM doesn't receive.  | 
RDI  | Whether Remote Defect Indication (RDI) is on or off   | 
PEER-MAC  | Remote MEP mac address  | 
TYPE  | Configured or auto learned  | 
Last modified date: 07/11/2023