OcNOS-SP : System Management Guide : System Management Command Reference : Erbium-doped Fiber Amplifier Commands : show interface IFNAME transceiver detail
show interface IFNAME transceiver detail
Use this command to display EDFA attributes and their thresholds
Command Syntax
show interface IFNAME transceiver detail
Parameters
IFNAME
Interface name
Default
None
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced before OcNOS version 6.3.0.
Example
OcNOS>show interface ce9/1 transceiver detail
Codes: * Not Qualified By IP Infusion, ** Not Supported By Module, -- No Power, - Not Applicable
 
...
 
Intf DDM InPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
---------------------------------------------------------------------------
ce9/1 Inactive* -2.00 -7.00 -9.00 -30.97 -32.22
 
Intf DDM OutPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
---------------------------------------------------------------------------
ce9/1 Inactive* -7.00 +10.00 +8.00 -20.00 -20.97
 
Intf DDM PumpBias AlertMax CritMax CritMin AlertMin
(Amp) (Amp) (Amp) (Amp) (Amp)
---------------------------------------------------------------------------
ce9/1 Inactive* +0.35 +0.49 +0.45 +0.00 +0.00
 
Intf DDM Gain AlertMax CritMax CritMin AlertMin
(dB) (dB) (dB) (dB) (dB)
---------------------------------------------------------------------------
ce9/1 Inactive* +12.00 +26.00 +25.00 +8.00 +7.00
 
Table 42-109 explains the output fields.
 
Table 42-109: show interface transceiver details output
Field
Description
Intf
Interface where the EDFA is present
DDM
Digital diagnostics monitor status for that particular interface
Inpwr
Input Power to the EDFA
OutPwr
Output Power from EDFA
PumpBias
Pump Bias
Gain
The total gain over the Input Power
 
 
Last modified date: 08/28/2023