OcNOS-SP : System Management Guide : System Management Command Reference : Smart SFP Commands : show interface transceiver details
show interface transceiver details
Use this command to display details of transceivers and threshold violations.
Command Syntax
show interface (IFNAME|) transceiver (detail|threshold violation|(protocol (stats|))|)(remote|)
Parameters
IFNAME
Interface name. If not specified, this command displays details of all connected transceivers.
detail
Transceiver information such as voltage, temperature, power, and current.
threshold violation
 
Transceiver threshold violations.
Codes
 
* Not Qualified By IP Infusion, ** Not Supported By Module.
Default
None
Command Mode
Exec mode
Applicability
This command was introduced before OcNOS version 6.2.0.
Example
OcNOS#sh int transceiver detail
Codes: * Not Qualified By IP Infusion, ** Not Supported By Module, -- No Power, - Not Applicable
 
 
Intf DDM Temp AlertMax CritMax CritMin AlertMin
(Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
---------------------------------------------------------------------------
 
ce0 Active* +22.52 +85.00 +80.00 -5.00 -10.00
ce2 Active +20.32 +75.00 +70.00 +0.00 -5.00
xe4 Active* +23.62 +95.00 +85.00 -40.00 -50.00
xe5 Active* +19.79 +100.00 +95.00 -35.00 -40.00
xe16 Active* +25.84 +95.00 +85.00 -10.00 -50.00
xe26 Active +19.01 +95.00 +90.00 -20.00 -25.00
 
 
 
Intf DDM Volt AlertMax CritMax CritMin AlertMin
(Volts) (Volts) (Volts) (Volts) (Volts)
---------------------------------------------------------------------------
ce0 Active* +3.314 +3.600 +3.500 +3.100 +2.900
ce2 Active +3.260 +3.630 +3.465 +3.135 +2.970
xe4 Active* +3.260 +3.600 +3.500 +3.100 +3.000
xe5 Active* +3.253 +3.600 +3.500 +2.900 +2.800
xe16 Active* +3.284 +3.630 +3.500 +3.030 +2.930
xe26 Active +3.289 +3.900 +3.700 +2.900 +2.700
 
 
Intf DDM Lane Curr AlertMax CritMax CritMin AlertMin
(mA) (mA) (mA) (mA) (mA)
-------------------------------------------------------------------------------------
ce0 Active* 1 +6.114 +15.000 +12.000 +2.000 +0.000
2 +6.120 +15.000 +12.000 +2.000 +0.000
3 +6.110 +15.000 +12.000 +2.000 +0.000
4 +6.116 +15.000 +12.000 +2.000 +0.000
ce2 Active 1 +7.464 +13.000 +11.000 +5.000 +3.000
2 +7.540 +13.000 +11.000 +5.000 +3.000
3 +7.444 +13.000 +11.000 +5.000 +3.000
4 +7.474 +13.000 +11.000 +5.000 +3.000
xe4 Active* - +6.100 +110.000 +100.000 +1.000 +1.000
xe5 Active* - +7.552 +15.000 +13.000 +2.000 +1.000
xe16 Active* - +5.800 +15.000 +12.000 +3.000 +2.000
xe26 Active - +7.050 +17.000 +14.000 +2.000 +1.000
 
 
 
Intf DDM Lane RxPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
-------------------------------------------------------------------------------------
ce0 Active* 1 -0.185 +4.400 +3.400 -13.298 -14.306
2 +0.342 +4.400 +3.400 -13.298 -14.306
3 +0.396 +4.400 +3.400 -13.298 -14.306
4 -2.927 +4.400 +3.400 -13.298 -14.306
ce2 Active 1 +1.302 +3.400 +2.400 -11.002 -14.001
2 +1.486 +3.400 +2.400 -11.002 -14.001
3 +1.581 +3.400 +2.400 -11.002 -14.001
4 +1.594 +3.400 +2.400 -11.002 -14.001
xe4 Active* - -1.890 +2.500 +0.500 -14.401 -16.402
xe5 Active* - -40.000 +3.000 +0.000 -13.002 -16.003
xe16 Active* - -- +2.000 +1.000 -14.401 -16.402
xe26 Active - -5.933 +1.000 -1.002 -18.013 -20.000
 
Intf DDM Lane TxPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
-------------------------------------------------------------------------------------
ce0 Active* 1 -0.085 +4.400 +3.400 -9.201 -10.205
2 -0.161 +4.400 +3.400 -9.201 -10.205
3 +0.217 +4.400 +3.400 -9.201 -10.205
4 +0.204 +4.400 +3.400 -9.201 -10.205
ce2 Active 1 +0.297 +5.000 +3.000 -8.000 -10.000
2 -0.078 +5.000 +3.000 -8.000 -10.000
3 +0.131 +5.000 +3.000 -8.000 -10.000
4 +0.323 +5.000 +3.000 -8.000 -10.000
xe4 Active* - -1.316 +2.500 +0.500 -8.199 -10.200
xe5 Active* - -2.299 +1.000 +0.000 -7.001 -8.000
xe16 Active* - -1.000 +2.500 +2.000 -8.199 -10.200
xe26 Active - -4.441 -2.000 -2.000 -11.024 -11.739
 
Intf DDM Lane Freq-Err AlertMax CritMax CritMin AlertMin
(GHz) (GHz) (GHz) (GHz) (GHz)
-------------------------------------------------------------------------------------
 
Intf DDM Lane Wave-Err AlertMax CritMax CritMin AlertMin
(nm) (nm) (nm) (nm) (nm)
-------------------------------------------------------------------------------------
 
Intf DDM Lane Tx Rx-LOS Tx-LOS
------------------------------------------------------------------------------
ce0 Active* 1 On Off Off
2 On Off Off
3 On Off Off
4 On Off Off
ce2 Active 1 On Off Off
2 On Off Off
3 On Off Off
4 On Off Off
xe4 Active* - On Off -
xe5 Active* - On On -
xe9 Inactive* - On On -
xe11 Inactive* - On On -
xe13 Inactive* - On On -
xe14 Inactive* - On On -
xe16 Active* - On On -
xe26 Active - On Off
 
Table 41-108 explains the output fields.
 
Table 41-108: show interface transceiver details output
Field
Description
Port
The number of the transceiver port.
Temp
Temperature in degrees Celsius of the transceiver.
Voltage
Voltage in Volts on the transceiver.
Current
Current in Milliamperes used by the transceiver.
Rx Power
Power received in Decibel-milliwatts (dBm) by the transceiver.
Tx Power
Power being transmitted in milliWatts by the transceiver.
High Alarm
The level that is needed to be reached to trigger a high alarm.
High Warn
The level that is needed to be reached to trigger a high warning.
Low Warn
The level that is needed to be reached to trigger a low warning.
Low Alarm
The level that is needed to be reached to trigger a low alarm.
Codes *
Not Qualified By IP Infusion, ** Not Supported By Module
 
 
Last modified date: 08/28/2023