OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : CFM and Y.1731 Commands : show ethernet cfm errors
show ethernet cfm errors
Use this command to verify the defects present in a MEP.
Command Syntax
show ethernet cfm errors (domain DOMAIN_NAME)
Parameters
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm errors domain 12345
Domain Name Level Vlan MEPID Defects
--------------------------------------------------------
12345 7 10 100 .....
 
 
Table 1-4 explains the output fields
Table 1-4: show ethernet cfm errors 
Field
Description
Domain Name
Maintenance Domain name
Level
MD Level
Vlan
Vlan identifier
MEPID
Maintenance End Point identifier
Defects
Defects in current MEP
 
Last modified date: 10/20/2023