show ethernet cfm maintenance-points local mip
Use this command to display information about the Maintenance Intermediate Points (MIPs) on a local interface.
Command Syntax
show ethernet cfm maintenance-points local (mip) (interface IFNAME| (level <0-7>) (ma-name MA_NAME|))
Parameters
IFNAME
Interface name.
<0-7>
Maintenance level.
MA_NAME
Maintenance association name. If ma-type is character string then maximum length of ma-name is 6 else if it's integer then maximum is 2-octets
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm maintenance-points local mip level 7 ma 123
Level VID Type Port MAC-Address
------------------------------------------------------
7 10 MIP xe3 0018.23ea.da36
7 10 MIP xe5 0018.23ea.da38
Table 1-10 explains the output fields.
Table 1-10: show ethernet cfm maintenance-points local mip
Field | Description |
---|
Level | MD level |
VID | VLAN identifier |
Type | MIP |
Port | Interface name |
MAC-Address | MAC address |