show ethernet cfm maintenance-points remote
Use this command to display information about a remote MEP.
Command Syntax
show ethernet cfm maintenance-points remote (mpid MEP_ID|) (domain DOMAIN_NAME)(ma-name MA_NAME)
Parameters
MEP_ID
Remote MEP identifier <1-8191>
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
MA name
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm maintenance-points remote domain 12345
MEPID RMEPID LEVEL VLAN Rx CCM RDI PEER-MAC TYPE
100 200 7 10 Yes False a82b.b579.fd2a Configured
Table 1-11 explains the output fields.
Table 1-11: show ethernet cfm maintenance-points remote
Field | Description |
---|
MEPID | MEP identifier |
RMEPID | Remote MEP identifier |
LEVEL | MD level |
VLAN | VLAN identifier |
Rx CCM | Yes if CCM receives, no if CCM doesn't receive. |
RDI | Whether Remote Defect Indication (RDI) is on or off |
PEER-MAC | Remote MEP mac address |
TYPE | Configured or auto learned |
Last modified date: 10/20/2023