OcNOS-SP : Carrier Ethernet Guide : Carrier Ethernet Command Reference : CFM and Y.1731 Commands : show ethernet cfm loss-measurement mep
show ethernet cfm loss-measurement mep
Use this command to display frame loss measurement statistics for a MEP.
Command Syntax
show ethernet cfm loss-measurement mep MEPID domain DOMAIN_NAME (ma-name MA_NAME)
Parameters
MEPID
Host MEP identifier <1-8191>
DOMAIN_NAME
Enter the name of the domain. Name must be of 5 characters if type is character-string otherwise no_name if domain-type is no-name1
MA_NAME
MA name
Command Mode
Exec mode and Privileged Exec mode
Applicability
This command was introduced in OcNOS version 3.0.
Example
#show ethernet cfm loss-measurement mep 201 domain 12345 ma 43982
MEP: 201 MA: 43982 CURRENT:
Measurement ID : 3
Measurement Type : slm
Elapsed time(sec) : 51
Start Time : 2018 Nov 19 22:37:31
Near End loss : 0
Far End loss : 0
Near End accumulated loss : 0 Far End accumulated loss : 0
 
HISTORY:
 
Measurement ID : 1
Measurement Type : slm
Elapsed time(sec) : 60
End Time : 2018 Nov 19 22:36:31
Near End loss : 0
Far End loss : 0
Near End accumulated loss : 0
Far End accumulated loss : 0
 
Measurement ID : 2
Measurement Type : slm
Elapsed time(sec) : 60
End Time : 2018 Nov 19 22:37:31
Near End loss : 0
Far End loss : 0
Near End accumulated loss : 0
Far End accumulated loss : 0
Table 1-6 explains the output fields.
Table 1-6: show ethernet cfm loss-measurement mep  
Field
Description
MEP
Maintenance End Point identifier
MA
Maintenance Association name
CURRENT:
Current loss measurement statistics
HISTORY:
Historic loss measurement statistics
Measurement ID
Sequence number
Measurement Type
Elapsed time
Elapsed time in seconds
Start Time
Start time
End Time
End time
Near End loss
Near end loss
Far End loss
Far end loss
Near End accumulated loss
Near end accumulated loss
Far End accumulated loss
Far end accumulated loss